131
OCH771
ON/OFF
TEMP
FAN
VANE
MODE
CHECK LOUVER
TEST RUN
AUTO STOP
AUTO START
h
min
CHECK
RESET
SET
CLOCK
Flow of function selection procedure
The flow of the function selection procedure is shown below. This example shows how to turn off
the function that raises the set temperature by 4 degrees during HEAT operation. (Mode 24: 2)
The procedure is given after the flow chart.
1
Check the function selection setting.
2
Switch to function selection mode.
(Enter address
˝
50
˝
in check mode,
then press the button.)
Check mode is the mode entered when
you press the CHECK button twice to display
˝
CHECK
˝
.
3
Specify unit No.
˝
01
˝
(since the function applies to unit 01).
(Set address
˝
01
˝
while still in check mode, then press the button.)
Note: You cannot specify the refrigerant address.
4
Select mode No.
˝
24
˝
(function that raises set temperature by 4 degrees during HEAT operation).
(Set address
˝
24
˝
while still in check mode, then press the button.)
6
Finished
8
End function selection mode.
(End check mode.)
YES
NO
Note: When you switch to function selection mode
on the wireless remote controller's operation
area, the unit ends function selection mode
automatically if nothing is input for 10 minutes
or longer.
5
Select setting No.
˝
02
˝
(OFF).
(Set address
˝
02
˝
while still in check mode, then press the button.)
Change
unit No.
YES
NO
7
h
min
h
h
[Flow of function selection procedure]
15-5-2. PAR-SL97A-E
Functions can be selected with the wireless remote controller. Function selection using wireless remote controller is available only for refriger-
ant system with wireless function. Refrigerant address cannot be specified by the wireless remote controller.
By setting unit number with the
min
button, specified indoor unit starts performing fan operation.
Detect which unit is assigned to which number using this function. If unit number is set to AL, all the indoor units in same
refrigerant system start performing fan operation simultaneously.
[Operating instructions]
1. Check the function settings.
2. Press the
CHECK
button twice continuously. → CHECK is lit and ˝00˝ blinks.
Press the TEMP
button once to set ˝50˝. Direct the wireless remote controller toward the receiver of the indoor unit and press
the
h
button.
3. Set the unit number.
Press the TEMP
button to set the unit number. (Press ˝01˝ to specify the indoor unit whose unit number is 01.)
Direct the wireless remote controller toward the receiver of the indoor unit and press the
min
button.
Notes:
1.
If a unit number that cannot be recognized by the unit is entered, 3 beeps of 0.4 seconds will be heard. Reenter the unit number setting.
2.
If the signal was not received by the sensor, you will not hear a beep or a ˝double beep˝ may be heard. Reenter the unit number setting.
4. Select a mode.
Press the TEMP
button to set a mode. Press ˝24˝ to turn on the function that raises the set temperature by 4 degrees
during heat operation. Direct the wireless remote controller toward the sensor of the indoor unit and press the
h
button.
→ The sensor-operation indicator will blink and beeps will be heard to indicate the current setting number.
Current setting number: 1 = 1 beep (1 second)
2 = 2 beeps (1 second each)
3 = 3 beeps (1 second each)
Notes:
1. If a mode number that cannot be recognized by the unit is entered, 3 beeps of 0.4 seconds will be heard. Reenter the mode number.
2. If the signal was not received by the sensor, you will not hear a beep or a ˝double beep˝ may be heard. Reenter the mode number.
5. Select the setting number.
Press the TEMP
button to select the setting number. (02: Not available)
Direct the wireless remote controller toward the receiver of the indoor unit and press the
h
button.
→ The sensor-operation indicator will blink and beeps will be heard to indicate the setting number.
Setting number: 1 = 2 beeps (0.4 seconds each)
2 = 2 beeps (0.4 seconds each, repeated twice)
3 = 2 beeps (0.4 seconds each, repeated 3 times)
Notes:
1. If a setting number that cannot be recognized by the unit is entered, the setting will turn back to the original setting.
2. If the signal was not received by the sensor, you will not hear a beep or a ˝double beep˝ may be heard. Reenter the setting number.
6. Repeat steps
4
and
5
to make an additional setting without changing unit number.
7. Repeat steps
3
to
5
to change unit number and make function settings on it.
8. Complete the function settings
Press
button.
Do not use the wireless remote controller for 30 seconds after completing the function setting.
Содержание PUZ-ZM60VHA2
Страница 21: ...21 OCH771 PUZ ZM60VHA2 ET ER UK PUZ ZM71VHA2 ET ER UK 6 OUTLINES AND DIMENSIONS 1 2 1 1 2 Unit mm ...
Страница 23: ...23 OCH771 PUZ ZM60VHA2 ET ER UK PUZ ZM71VHA2 ET ER UK 7 WIRING DIAGRAM ...
Страница 24: ...24 OCH771 PUZ ZM100VKA2 ET ER UK ...
Страница 25: ...25 OCH771 PUZ ZM125VKA2 ET ER UK PUZ ZM140VKA2 ET ER UK ...
Страница 26: ...26 OCH771 PUZ ZM100YKA2 ET ER UK PUZ ZM125YKA2 ET ER UK PUZ ZM140YKA2 ET ER UK ...
Страница 27: ...27 OCH771 PUZ ZM200YKA2 UK PUZ ZM250YKA2 UK ...