[4-7 BC Controller Electrical Wiring Diagrams ]
24 -
chapter 4
HWE18220_GB
4 Electrical Components and Wiring Diagrams
(5) CMB-P108NU-JA1 model
t°
t°
t°
t°
LD1:CPU in
operation
SVM1
M
M
X12
X1
1
X35
X34
X09
X10
X33
X07
X08
X06
X05
X32
X31
X03
X04
X02
X01
X30
X21
X60
X36
X13
X14
X37
X15
X16
X18
X17
X38
X20
X19
X39
U
ZNR02
U
ZNR01
(Y
ellow)
CN03
3
1
CN33(Red)
CN34(Black)
CN35(Blue)
CN39
60Hz
~208V
-230V
POWER SUPPL
Y
BREAKER(16A)
PULL
BOX
FUSE(16A)
T
O
NEXT
INDOOR UNIT
TB01
L2
L1
CN36(Green)
CN30(Black)
CN31(Y
ellow)
CN29(Green)
CN28(Blue)
CN27(Red)
(Red)
CNTR
DSA
M1
M2
TB02
S(SHIELD)
Indoor/outdoor
T
ransmission line
(Red)
CN05
(Y
ellow)
CN07
(Black)
CNP1
SW2
SW1
1
10
F01
250V
AC
6.3A
F
2
1
3
2
3
1
REL. B
1
3
CN26
CN38
3
1
CN12
5
3
1
7654321
1
2
3
4
5
6
7
CN50CN50
PS3
PS1
TR
TH16
TH15
TH12
TH1
1
CN1
1
CN10
CN02
1
2
321
1
2
3
4
8
7
6
5
4
3
2
1
CNP3
3
2
1
3
2
1
LEV1
LEV3
1
2
3
45
6
1
2
3
45
6
CONT
. B
CN52
1
2
3
4
5
6
7
1
2
3
4
33
2
1
2
1
16
15
14
7
6
5
13
12
11
10
9
8
16
15
14
7
6
5
10
9
8
13
12
11
2
3
4
1
2
3
4
2
3
4
2
3
4
1
1
1
7
5
3
1
7
5
3
1
7
5
3
1
7
5
3
1
7
5
3
1
7
1
4
2
3
1
4
2
3
1
2
3
4
5
3
1
1
2
3
4
1
2
3
4
13
14
15
10
11
12
9
7
86
5
4
4
87
6
5
12
1
1
10
9
15
14
13
16 16
CN32
57
3
17
5
3
17
5
3
17
5
1
33
3
CN46(Y
ellow)
3
1
3
1
1
2
3
4 41
2
3
1
2
3
1
2
3
1
2
Z1
TYP1
X62
X61
CN47
1
3
5
6
5
6 65
4
5
6
4
5
6
SVM1b
7
8 87
M
LEV4
1
2
3
4
5
6
(Green)
CN08
SW4
SW5
SW6
2
1
CN13
(Red)
G
T1
T2
T3
T4
T5
T6
SV1B
SV1A
SV1C
1
2
3
4
SV2C
SV2A
SV2B
4
3
2
1
SV3C
SV3A
SV3B
4
3
2
1
SV4C
SV4A
SV4B
4
3
2
1
SV5C
SV5A
SV5B
4
3
2
1
SV6C
SV6A
SV6B
4
3
2
1
T7
T8
SV7C
SV7A
SV7B
43
2
1
SV8C
SV8A
SV8B
43
2
1
(Symbol explanation)
Circuit
board
BC controller
REL.B
Relay
Pressure sensor
TR
TH1
1,12,15,16
LEV1,3,4
PS1,3
SV1~8A,B,C
Name
T
ransformer
Thermister sensor
Expansion valve
Solenoid valve
TB01
T
e
rminal block
(for power source)
TB02
T
e
rminal block
(for T
ransmission)
CONT
.B
SVM1,SVM1b
Solenoid valve
T
e
rminal
T1~8
Fuse AC250V
6.3A
F
F01
Function setting connector
Z1
Symbol
Note 1.
TB02 is transmission terminal block.
Never connect power line to it.
2.
The initial set values of switch on CONT
. B are as follows.
SW1:0
SW2:0
Содержание PURY-HP144
Страница 1: ......
Страница 9: ...viii ...
Страница 13: ...HWE18220_GB ...
Страница 29: ...HWE18220_GB ...
Страница 77: ...HWE18220_GB ...
Страница 95: ...HWE18220_GB ...
Страница 125: ...HWE18220_GB ...
Страница 153: ...HWE18220_GB ...
Страница 163: ...HWE18220_GB ...
Страница 343: ...HWE18220_GB ...
Страница 361: ...HWE18220_GB ...
Страница 398: ......