2
Contents
1. Safety precautions
Ź
Before installing the unit, make sure you read all the “Safety precautions”.
Ź
Please report to or take consent by the supply authority before connec-
tion to the system.
After installation work has been completed, explain the “Safety Precautions” use,
and maintenance of the unit to the customer according to the information in the
Operation Manual and perform the test run to ensure normal operation. Both the
Installation Manual and Operation Manual must be given to the user for keeping.
These manuals must be passed on to subsequent users.
: Indicates a part which must be grounded.
Warning:
&DUHIXOO\UHDGWKHODEHOVDI¿[HGWRWKHPDLQXQLW
Warning:
7KH XQLW PXVW QRW EH LQVWDOOHG E\ WKH XVHU $VN D GHDOHU RU DQ DXWKRUL]HG
technician to install the unit. If the unit is installed incorrectly, water leakage,
HOHFWULFVKRFNRU¿UHPD\UHVXOW
)RULQVWDOODWLRQZRUNIROORZWKHLQVWUXFWLRQVLQWKH,QVWDOODWLRQ0DQXDODQGXVH
WRROVDQGSLSHFRPSRQHQWVVSHFL¿FDOO\PDGHIRUXVHZLWK5$UHIULJHUDQW
7KH5$UHIULJHUD)&V\VWHPLVSUHVVXUL]HGWLPHVWKHSUHV
-
sure of usual refrigerants. If pipe components not designed for R410A refrig-
erant are used and the unit is not installed correctly, the pipes may burst and
FDXVHGDPDJHRULQMXULHV,QDGGLWLRQZDWHUOHDNDJHHOHFWULFVKRFNRU¿UH
may result.
7KHXQLWPXVWEHLQVWDOOHGDFFRUGLQJWRWKHLQVWUXFWLRQVLQRUGHUWRPLQLPL]H
the risk of damage from earthquakes, typhoons, or strong winds. An incor-
rectly installed unit may fall down and cause damage or injuries.
The unit must be securely installed on a structure that can sustain its weight.
If the unit is mounted on an unstable structure, it may fall down and cause
damage or injuries.
If the air conditioner is installed in a small room, measures must be taken to
SUHYHQWWKHUHIULJHUDQWFRQFHQWUDWLRQLQWKHURRPIURPH[FHHGLQJWKHVDIHW\OLPLW
in the event of refrigerant leakage. Consult a dealer regarding the appropriate
PHDVXUHVWRSUHYHQWWKHDOORZDEOHFRQFHQWUDWLRQIURPEHLQJH[FHHGHG
6KRXOGWKHUHIULJHUDQWOHDNDQGFDXVHWKHFRQFHQWUDWLRQOLPLWWREHH[FHHGHG
KD]DUGVGXHWRODFNRIR[\JHQLQWKHURRPPD\UHVXOW
9HQWLODWHWKHURRPLIUHIULJHUDQWOHDNVGXULQJRSHUDWLRQ,IUHIULJHUDQWFRPHV
LQWRFRQWDFWZLWKDÀDPHSRLVRQRXVJDVHVZLOOEHUHOHDVHG
$OOHOHFWULFZRUNPXVWEHSHUIRUPHGE\DTXDOL¿HGWHFKQLFLDQDFFRUGLQJWR
local regulations and the instructions given in this manual. The units must
be powered by dedicated power lines and the correct voltage and circuit
EUHDNHUVPXVWEHXVHG3RZHUOLQHVZLWKLQVXI¿FLHQWFDSDFLW\RULQFRUUHFW
HOHFWULFDOZRUNPD\UHVXOWLQHOHFWULFVKRFNRU¿UH
%H VXUH WR FRQQHFW WKH SRZHU VXSSO\ FRUGV DQG WKH FRQQHFWLQJ ZLUHV IRU
WKHLQGRRUXQLWVRXWGRRUXQLWVDQGEUDQFKER[HVGLUHFWO\WRWKHXQLWVQR
intermediate connections).
Intermediate connections can lead to communication errors if water enters
WKH FRUGV RU ZLUHV DQG FDXVHV LQVXI¿FLHQW LQVXODWLRQ WR JURXQG RU D SRRU
electrical contact at the intermediate connection point.
(If an intermediate connection is necessary, be sure to take measures to
prevent water from entering the cords and wires.)
8VH&FRSSHUSKRVSKRUXVIRUFRSSHUDQGFRSSHUDOOR\VHDPOHVVSLSHV
to connect the refrigerant pipes. If the pipes are not connected correctly, the
unit will not be properly grounded and electric shock may result.
8VHRQO\VSHFL¿HGFDEOHVIRUZLULQJ7KHZLULQJFRQQHFWLRQVPXVWEHPDGH
securely with no tension applied on the terminal connections. Also, never
splice the cables for wiring (unless otherwise indicated in this document).
)DLOXUHWRREVHUYHWKHVHLQVWUXFWLRQVPD\UHVXOWLQRYHUKHDWLQJRUD¿UH
7KHWHUPLQDOEORFNFRYHUSDQHORIWKHRXWGRRUXQLWPXVWEH¿UPO\DWWDFKHG,I
the cover panel is mounted incorrectly and dust and moisture enter the unit,
HOHFWULFVKRFNRU¿UHPD\UHVXOW
:KHQ LQVWDOOLQJ RU UHORFDWLQJ RU VHUYLFLQJ WKH RXWGRRU XQLW XVH RQO\ WKH
VSHFL¿HGUHIULJHUDQW5$WRFKDQJHWKHUHIULJHUDQWOLQHV'RQRWPL[LW
with any other refrigerant and do not allow air to remain in the lines.
,IDLULVPL[HGZLWKWKHUHIULJHUDQWWKHQLWFDQEHWKHFDXVHRIDEQRUPDOKLJKSUHV
-
VXUHLQWKHUHIULJHUDQWOLQHDQGPD\UHVXOWLQDQH[SORVLRQDQGRWKHUKD]DUGV
7KHXVHRIDQ\UHIULJHUDQWRWKHUWKDQWKDWVSHFL¿HGIRUWKHV\VWHPZLOOFDXVH
mechanical failure or system malfunction or unit breakdown. In the worst
case, this could lead to a serious impediment to securing product safety.
8VHRQO\DXWKRUL]HGDFFHVVRULHVDQGDVNDGHDOHURUDQDXWKRUL]HGWHFKQL
-
cian to install them. If accessories are incorrectly installed, water leakage,
HOHFWULFVKRFNRU¿UHPD\UHVXOW
'RQRWDOWHUWKHXQLW&RQVXOWDGHDOHUIRUUHSDLUV,IDOWHUDWLRQVRUUHSDLUVDUH
QRWSHUIRUPHGFRUUHFWO\ZDWHUOHDNDJHHOHFWULFVKRFNRU¿UHPD\UHVXOW
The user should never attempt to repair the unit or transfer it to another location.
,IWKHXQLWLVLQVWDOOHGLQFRUUHFWO\ZDWHUOHDNDJHHOHFWULFVKRFNRU¿UHPD\
result. If the air conditioner must be repaired or moved, ask a dealer or an
DXWKRUL]HGWHFKQLFLDQ
$IWHULQVWDOODWLRQKDVEHHQFRPSOHWHGFKHFNIRUUHIULJHUDQWOHDNV,IUHIULJHU
-
DQWOHDNVLQWRWKHURRPDQGFRPHVLQWRFRQWDFWZLWKWKHÀDPHRIDKHDWHURU
portable cooking range, poisonous gases will be released.
1.1. Before installation
Caution:
'R QRW XVH WKH XQLW LQ DQ XQXVXDO HQYLURQPHQW ,I WKH DLU FRQGLWLRQHU LV
LQVWDOOHGLQDUHDVH[SRVHGWRVWHDPYRODWLOHRLOLQFOXGLQJPDFKLQHRLORU
VXOIXULFJDVDUHDVH[SRVHGWRKLJKVDOWFRQWHQWVXFKDVWKHVHDVLGHRUDUHDV
ZKHUHWKHXQLWZLOOEHFRYHUHGE\VQRZWKHSHUIRUPDQFHFDQEHVLJQL¿FDQWO\
reduced and the internal parts can be damaged.
'R QRW LQVWDOO WKH XQLW ZKHUH FRPEXVWLEOH JDVHV PD\ OHDN EH SURGXFHG
ÀRZRUDFFXPXODWH,IFRPEXVWLEOHJDVDFFXPXODWHVDURXQGWKHXQLW¿UHRU
H[SORVLRQPD\UHVXOW
Warning:
Describes precautions that must be observed to prevent danger of injury or
death to the user.
Caution:
Describes precautions that must be observed to prevent damage to the unit.
7KHRXWGRRUXQLWSURGXFHVFRQGHQVDWLRQGXULQJWKHKHDWLQJRSHUDWLRQ0DNH
sure to provide drainage around the outdoor unit if such condensation is
likely to cause damage.
:KHQLQVWDOOLQJWKHXQLWLQDKRVSLWDORUFRPPXQLFDWLRQVRI¿FHEHSUHSDUHG
for noise and electronic interference. Inverters, home appliances, high-
frequency medical equipment, and radio communications equipment can
cause the air conditioner to malfunction or breakdown. The air conditioner
may also affect medical equipment, disturbing medical care, and communi-
cations equipment, harming the screen display quality.
1.2. Before installation (relocation)
Caution:
%H H[WUHPHO\ FDUHIXO ZKHQ WUDQVSRUWLQJ WKH XQLWV RU PRUH SHUVRQV DUH
needed to handle the unit, as it weighs 20 kg, 44 lbs or more. Do not grasp
the packaging bands. Wear protective gloves to remove the unit from the
SDFNDJLQJDQGWRPRYHLWDV\RXFDQLQMXUH\RXUKDQGVRQWKH¿QVRUWKH
edge of other parts.
%HVXUHWRVDIHO\GLVSRVHRIWKHSDFNDJLQJPDWHULDOV3DFNDJLQJPDWHULDOV
such as nails and other metal or wooden parts may cause stabs or other
injuries.
7KHEDVHDQGDWWDFKPHQWVRIWKHRXWGRRUXQLWPXVWEHSHULRGLFDOO\FKHFNHG
for looseness, cracks or other damage. If such defects are left uncorrected,
the unit may fall down and cause damage or injuries.
'RQRWFOHDQWKHDLUFRQGLWLRQHUXQLWZLWKZDWHU(OHFWULFVKRFNPD\UHVXOW
7LJKWHQDOOÀDUHQXWVWRVSHFL¿FDWLRQXVLQJDWRUTXHZUHQFK,IWLJKWHQHGWRR
PXFKWKHÀDUHQXWFDQEUHDNDIWHUDQH[WHQGHGSHULRGDQGUHIULJHUDQWFDQ
leak out.
&RQ¿UPDWLRQRISDUWVDWWDFKHG
In addition to this manual, the following part is supplied with the outdoor unit.
It is used for grounding the S terminal of transmission terminal block TB7.
For detail refers to “6. Electrical work”.
Grounding lead wire
1. Safety precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2. Installation location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3. Installing the outdoor unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4. Installing the refrigerant piping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
5. Drainage piping work . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
6. Electrical work . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
7. Test run . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
8. Special Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15