<Dual-In-Line Package Intelligent Power Module>
1200V Mini DIPIPM with BSD Series APPLICATION NOTE
Publication Date: September 2015
9
Table 2-1-4 shows the typical control part characteristics of PSS20S71F6.
Table 2-1-4 Control (Protection) characteristics of PSS20S71F6
CONTROL (PROTECTION) PART
(T
j
= 25°C, unless otherwise noted)
Symbol Parameter
Condition
Limits
Unit
Min. Typ. Max.
I
D
Circuit current
Total of V
P1
-V
NC
, V
N1
-V
NC
V
D
=15V, V
IN
=0V -
-
6.00
mA
V
D
=15V, V
IN
=5V -
-
6.00
I
DB
Each part of V
UFB
- V
UFS
,
V
VFB
- V
VFS
, V
WFB
- V
WFS
V
D
=V
DB
=15V, V
IN
=0V -
-
0.55
V
D
=V
DB
=15V, V
IN
=5V -
-
0.55
V
SC(ref)
Short circuit trip level
V
D
= 15V
(Note 1)
0.45 0.48 0.51
V
UV
DBt
P-side Control supply
under-voltage protection(UV)
T
j
≤
125°C
Trip level
10.0
-
12.0
V
UV
DBr
Reset
level
10.5
-
12.5
V
UV
Dt
N-side Control supply
under-voltage protection(UV)
Trip level
10.3
-
12.5
V
UV
Dr
Reset
level
10.8
-
13.0
V
V
OT
Temperature
output
Pull down R=5k
Ω
(Note 2)
LVIC Temperature=85
C
2.51 2.64 2.76
V
V
FOH
Fault output voltage
V
SC
= 0V, F
O
terminal pulled up to 5V by 10k
Ω
4.9
-
-
V
V
FOL
V
SC
= 1V, I
FO
= 1mA
-
-
0.95
V
t
FO
Fault output pulse width
C
FO
=22nF
(Note 3)
1.6 2.4 -
ms
I
IN
Input
current
V
IN
= 5V
0.70
1.00
1.50
mA
V
th(on)
ON threshold voltage
Applied between U
P
, V
P
, W
P
, U
N
, V
N
, W
N
-V
NC
- - 3.5
V
V
th(off)
OFF threshold voltage
0.8 - -
V
F
Bootstrap Di forward voltage
I
F
=10mA including voltage drop by limiting resistor
0.5 0.9 1.3 V
R
Built-in limiting resistance
Included in bootstrap Di
16
20
24
Ω
Note 1 : SC protection works only for N-side IGBT. Please select the external shunt resistance such that the SC trip-level is less than 2 times of the current rating.
Note
2 : DIPIPM don't shutdown IGBTs and output fault signal automatically when temperature rises excessively. When temperature exceeds the protective level that
user defined, controller (MCU) should stop the DIPIPM.
3 : Fault signal Fo outputs when SC or UV protection works. Fo pulse width is different for each protection modes. At SC failure, Fo pulse width is a fixed width
which is specified by the capacitor connected to C
FO
terminal. (
C
FO
=9.1 x 10
-6
x t
FO
[F])
, but at UV failure, Fo outputs continuously until recovering from UV
state. (But minimum Fo pulse width is the specified time by C
FO
.)
Recommended operating conditions of PSS10S72FT are given in Table 2-1-5. It is highly recommended to
operate the modules within these conditions so as to ensure DIPIPM safe operation.
Table 2-1-5 Recommended operating conditions of PSS10S72FT
RECOMMENDED OPERATION CONDITIONS
Symbol Parameter
Condition
Limits
Unit
Min. Typ. Max.
V
CC
Supply voltage
Applied between P-NU, NV, NW
350 600 800
V
V
D
Control supply voltage
Applied between V
P1
-V
NC
, V
N1
-V
NC
13.5 15.0 16.5
V
V
DB
Control supply voltage
Applied between V
UFB
-V
UFS
, V
VFB
-V
VFS
, V
WFB
-V
WFS
13.0 15.0 18.5
V
∆
V
D
,
∆
V
DB
Control supply variation
-1 - +1
V/
μ
s
t
dead
Arm shoot-through blocking time
For each input signal
3.0 - -
μ
s
f
PWM
PWM input frequency
T
C
≤
100°C, T
j
≤
125°C
- - 20
kHz
I
O
Allowable
r.m.s.
current
V
CC
= 600V, V
D
= 15V, P.F = 0.8,
Sinusoidal PWM
T
C
≤
100°C, T
j
≤
125°C
(Note1)
f
PWM
= 5kHz
- - 5.3
Arms
f
PWM
= 15kHz
- - 3.6
PWIN(on)
Minimum input pulse width
(Note 2)
2.0 - -
μ
s
PWIN(off)
200V
V
CC
350V,
13.5V
V
D
16.5V,
13.0V
V
DB
18.5V,
-20
C
Tc
100
C,
N-line wiring inductance
less than 10nH
(
Note 3
)
Below rated current
2.5 - -
Between rated current
and 1.7 times of rated
current
2.9 - -
V
NC
V
NC
variation
Between V
NC
-NU, NV, NW (including surge)
-5.0 - +5.0
V
T
j
Junction
temperature
-20 - +125
°C
Note 1: Allowable r.m.s. current depends on the actual application conditions.
2: DIPIPM might not make response if the input signal pulse width is less than PWIN(on)
3: IPM might make delayed response or no response for the input signal with off pulse width less than PWIN(off). Please refer below about delayed response.
Delayed Response Against Shorter Input Off Signal Than PWIN(off) (P-side only)