[
X
LED Monitor Display on the Heat source Unit Board ]
- 362 -
HWE09080
11
11
01
000
00
0
Ex
te
rnal
si
gn
al
(O
pe
n i
npu
t
c
o
n
ta
c
t
po
in
t)
Con
tact
po
in
t d
e
-
mand
Lo
w-
noi
s
e
mode
(C
apa
ci
ty
p
ri
o
ri
ty
)
Coo
lin
g
-
he
at
ing
ch
an
geo
ve
r
(C
oo
ling
)
C
o
ol
in
g-
h
eat
in
g
ch
ang
eo
ve
r
(H
e
a
ti
ng
)
AA
12
00
11
000
00
0
Ex
te
rnal
si
gn
al
(O
pe
n i
npu
t
c
o
n
ta
c
t
po
in
t)
Pump
in
te
r-
lo
ck
(Co
n-
ta
c
t: op
en
)
Lo
w-
noi
s
e
mode
(Q
ui
et pr
io
ri-
ty
)
AA
13
10
11
000
00
0
14
01
11
000
00
0
He
at
sou
rc
e un
it
op
er
a-
ti
on
st
at
us
B
C
op
er
a-
ti
on
si
gn
al
3-
min
ute
s
re
st
ar
t mo
de
Co
mpr
es
so
r
in
op
er
at
io
n
Prelimi
nary
er
ro
r
E
rro
r
3-
min
ut
es
re
sta
rt
a
fte
r
in
s
tant
a
-
n
eou
s p
o
we
r
fa
ilu
re
Pr
el
imin
ar
y
lo
w pr
es
-
su
re
e
rr
o
r
AA
15
11
11
000
00
0
O
C/
OS
i
d
e
n
ti
fi
c
a
ti
o
n
OC
/O
S
A
A
16
00
00
100
00
0
In
d
oor
un
it
ch
ec
k
To
p
U
ni
t No
. 1
U
n
it No
. 2
U
n
it
No
.
3
U
n
it
No.
4
U
n
it
No.
5
U
nit
No.
6
U
ni
t No
. 7
U
n
it No
. 8
B
Th
e
la
mp t
h
a
t c
o
rre
-
s
p
o
n
d
s
to
th
e un
it
t
hat
ca
me to an
a
b
n
o
rm
al
st
op
lig
ht
s.
T
h
e
l
a
mp
goe
s of
f whe
n
th
e er
ro
r i
s
re
se
t.
Ea
ch
u
n
it
t
h
a
t c
o
me
s
to
an
a
b
n
o
rm
al
un
it
will
be
g
iven
a se
que
nt
ia
l num-
be
r
in
as
ce
nd
in
g or
de
r
s
tar
ti
ng
wit
h
1
.
Bottom
U
nit No. 9
U
ni
t No. 10
Unit No. 11
Unit No. 12
Unit
N
o
.
1
3
Unit
No
.
1
4
Un
it No
. 1
5
Un
it No
. 16
17
10
00
100
00
0
T
o
p
U
n
it No
. 1
7
Un
it No. 18
Un
it No. 19
Unit No. 20
Unit
N
o
.
2
1
Unit
No
.
2
2
Un
it No
. 2
3
Un
it No
. 24
B
o
ttom
Un
it No
. 2
5
Un
it No. 26
Un
it No. 27
Unit No. 28
Unit
N
o
.
2
9
Unit
No
.
3
0
Un
it No
. 3
1
Un
it No
. 32
18
01
00
100
00
0
T
o
p
U
n
it No
. 3
3
Un
it No. 34
Un
it No. 35
Unit No. 36
Unit
N
o
.
3
7
Unit
No
.
3
8
Un
it No
. 3
9
Un
it No
. 40
Bottom
U
nit No.
41
Unit No. 42
Unit
No.4
3
Unit
No.
44
Unit N
o
. 4
5
Unit No
. 4
6
Un
it
No4
7
U
n
it
No
.
48
19
11
00
100
00
0
T
o
p
U
n
it No
. 4
9
Un
it No. 50
Bo
tto
m
20
00
10
100
00
0
In
d
oor
un
it
Op
er
at
ion
mode
To
p
U
ni
t No
. 1
U
n
it No
. 2
U
n
it
No
.
3
U
n
it
No.
4
U
n
it
No.
5
U
nit
No.
6
U
ni
t No
. 7
U
n
it No
. 8
B
Lit
d
u
ri
ng
c
o
o
lin
g
L
it du
ri
n
g
he
at
in
g
Un
lit wh
ile
th
e
un
it
is
sto
p
p
e
d
or
in
th
e
fa
n
mode
Bottom
U
nit No. 9
U
ni
t No. 10
Unit No. 11
Unit No. 12
Unit
N
o
.
1
3
Unit
No
.
1
4
Un
it No
. 1
5
Un
it No
. 16
21
10
10
100
00
0
T
o
p
U
n
it No
. 1
7
Un
it No. 18
Un
it No. 19
Unit No. 20
Unit
N
o
.
2
1
Unit
No
.
2
2
Un
it No
. 2
3
Un
it No
. 24
B
o
ttom
Un
it No
. 2
5
Un
it No. 26
Un
it No. 27
Unit No. 28
Unit
N
o
.
2
9
Unit
No
.
3
0
Un
it No
. 3
1
Un
it No
. 32
22
01
10
100
00
0
T
o
p
U
n
it No
. 3
3
Un
it No. 34
Un
it No. 35
Unit No. 36
Unit
N
o
.
3
7
Unit
No
.
3
8
Un
it No
. 3
9
Un
it No
. 40
Bottom
U
nit No.
41
Unit No. 42
Unit
No.4
3
Unit
No.
44
Unit N
o
. 4
5
Unit No
. 4
6
Un
it
No4
7
U
n
it
No
.
48
23
11
10
100
00
0
T
o
p
U
n
it No
. 4
9
Un
it No. 50
Bo
tto
m
C
u
rrent
dat
a
No
.
SW1
Ite
m
Disp
la
y
Unit
(A
, B)
*1
Re
m
a
rk
s
12
34
567
89
0
L
D1
LD
2
L
D3
LD4
L
D
5
L
D6
L
D
7
L
D
8
O
C
OS
*1
A:
Th
e co
ndi
ti
on o
f ei
th
e
r OC o
r OS i
s
di
sp
la
ye
d i
n
d
iv
id
u
a
lly
. B:
Th
e co
ndi
ti
on o
f t
h
e
e
n
ti
re
r
e
fr
ig
er
an
t sy
st
e
m
i
s
d
is
p
la
y
e
d.
Содержание PQHY-P120THMU-A
Страница 1: ......
Страница 11: ... 2 ...
Страница 25: ... 16 ...
Страница 83: ... 74 ...
Страница 102: ... III Heat source Unit Components 93 HWE09080 GB 2 RELAY BOARD RELAY 4 board 3 RELAY BOARD RELAY 10 board ...
Страница 103: ... 94 III Heat source Unit Components GB HWE09080 ...
Страница 105: ... 96 ...
Страница 113: ... 104 IV Remote Controller GB HWE09080 ...
Страница 115: ... 106 ...
Страница 130: ... 121 HWE09080 GB VI Refrigerant Circuit 1 Refrigerant Circuit Diagram 123 2 Principal Parts and Functions 126 ...
Страница 131: ... 122 ...
Страница 143: ... 134 VI Refrigerant Circuit GB HWE09080 ...
Страница 145: ... 136 ...
Страница 181: ... 172 VII Control GB HWE09080 ...
Страница 183: ... 174 ...
Страница 235: ... 226 ...
Страница 366: ... 357 HWE09080 GB X LED Monitor Display on the Heat source Unit Board 1 How to Read the LED on the Service Monitor 359 ...
Страница 367: ... 358 ...
Страница 414: ......