Airflow for Static Pressure
Connect
Program
Settings
Home
Cancel
Back
Is the unit ductless?
Living Room
YES
NO, SET AIRFLOW
Set airflow for ducted models
including MVZ and SEZ.
1
Unit
Program
Settings
Home
Site
Living
Room
Signal:
Strong
Auto Mode:
No
Display Offset:
0º
ADVANCED
DELETE UNIT
Advanced
Program
Settings
Home
Unit
Living
Room
Dehumidify/Dry:
No
Pressure
Program
Settings
Home
Back
DELETE SETTING
Living Room
Airflow for the PEAD model indoor
unit is set for external static
pressure of 0.2 inches WC.
Set Airflow
2
Min Cool Setpoint:
60º
Max Heat Setpoint:
88º
Thermal Off Fan:
Very low…
Static Pressure:
0.2
inches
System Type:
CCooooll aanndd H
Heeaatt
4
FFiirrm
mw
waarree:: 00..0000..00
3
Airflow can be set when Adding an Indoor Unit or after all the units have been added. Airflow can be set for
SEZ, PEA, PEAD, MVZ, SVZ, and PVA units using kumo cloud
®
. For other ducted models, see the install
manual and set the dip switches before adding the units in kumo cloud.
1. To Add Indoor Units, see the
Add Indoor Units
section. Then, tap
No, Set Airflow
.
Or
2. Access the indoor unit settings as shown in the
Access Unit Settings
section, then tap
Advanced
.
3. Tap
Static Pressure
.
4. Tap
Set Airflow
.
SEZ or PEA
PEAD
MVZ or PVA -AA# models
MVZ or PVA -AA4
Connect
Program
Settings
Home
Cancel
Back
Living Room
Which type of unit is this?
5
Back
Connect
Cancel
Living Room
Adjust blower as needed for
static pressure.
0.14 inch WC
0.2 inch WC
7
0.28 inch WC
SAVE
8
Home
Program
Settings
Connect
Program
Settings
Home
Cancel
Back
Living Room
How is the air handler installed?
Vertical position
Horizontal left or right
Downflow position
6
5. Tap the
Unit Model Type
. For MVZ, SVZ or PVA units, note the model number; newer models handle
backup heat differently than model numbers ending in AA4.
6. For MVZ, SVZ, or PVA units, select the
Position
.
7. Tap the appropriate
Pressure Setting
. For MVZ or PVA - AA# models, follow the prompts to set backup
heat options (not shown).
8.
If setting airflow while Adding an Indoor Unit, tap
Save
to move on to complete the Add Unit. See the
Add Unit
section.