3-2. FLARE CONNECTION

1) Cut the copper pipe as straight as possible with a pipe cutter.  (Fig. 1, 2)
2) Remove all burrs from the cut section of the pipe, ensuring that precautions are taken to 

avoid getting metal shavings into the piping. (Fig. 3)

5HPRYHÀDUHQXWVDWWDFKHGWRLQGRRUDQGRXWGRRUXQLWVWKHQSXWWKHPRQSLSH

4) Flaring work (Fig. 4, 5). Firmly hold copper pipe in the dimension shown in the table. 

Select A mm from the table according to the tool you use.

5) Check

‡ &RPSDUHWKHÀDUHGZRUNZLWK)LJ
‡ ,IÀDUHLVGHIHFWLYHFXWRIIWKHVHFWLRQDQGUHSHDWSURFHGXUH

3-3. PIPE CONNECTION

‡ )DVWHQÀDUHQXWZLWKDWRUTXHZUHQFKDVVSHFL¿HGLQWKHWDEOHDERYH
‡ :KHQIDVWHQHGWRRWLJKWÀDUHQXWPD\HYHQWXDOO\EUHDNDQGFDXVHUHIULJHUDQWOHDNDJH

Indoor unit connection

Connect both liquid and gas piping to indoor unit.
• Apply a thin coat of refrigerant oil (J) on the seat surface of pipe.

‡ 7RFRQQHFW¿UVWDOLJQWKHFHQWHUWKHQWLJKWHQWKH¿UVWWRWXUQVRIÀDUHQXW

• Use tightening torque table above as a guideline for indoor unit side joints, and tighten 

XVLQJWZRZUHQFKHV([FHVVLYHWLJKWHQLQJGDPDJHVWKHÀDUHVHFWLRQ

Outdoor unit connection

Connect pipes to stop valve pipe joint of the outdoor unit following the same procedure 
detailed in Indoor unit connection.
• For tightening, use a torque wrench or spanner.

3-4. INSULATION AND TAPING

1) Cover piping joints with pipe cover.
2) For outdoor unit side, insulate the piping, including valves.
3) Apply piping tape (G) starting from the connection on the outdoor unit.

• When piping has to be installed through a ceiling, closet or where the temperature 

DQGKXPLGLW\DUHKLJKXVHDGGLWLRQDO¿HOGVXSSOLHGLQVXODWLRQWRSUHYHQWFRQGHQVD

-

tion.

Copper
pipe

Good

Tilted

No good

Fig. 1

Fig. 2

Burr

Copper pipe

Spare reamer

Pipe cutter

Fig. 4

Fig. 3

Smooth all around

Even length 
all around

Inside is shin-
ing without any 
scratches.

Fig. 5

Fig. 6

Flare nut

Die

Copper pipe

Clutch type

Flaring tool

Wing nut type

Pipe diameter 

inch (mm)

Nut

inch

(mm)

A inch (mm)

Tightening torque

Clutch

type tool 

for R410A

Clutch

type tool 

for R22

Wing nut 

type tool 

for R22

N•m

ft•lb

(kgf•cm)

ø 1/4  (6.35)

1/4

(17)

0 to 0.02

(0 to 0.5)

0.04 to 

0.06

(1.0 to 

1.5)

0.06 to 

0.08

(1.5 to 

2.0)

13.7 to 

17.7

10 to 13

(140 to 

180)

ø 3/8  (9.52)

3/8

(22)

34.3 to 

41.2

25 to 30

(350 to 

420)

ø 1/2  (12.7)

1/2

(26)

0.08 to 

0.10

(2.0 to 

2.5)

49.0 to 

56.4

36 to 42

(500 to 

575)

ø 5/8  (15.88)

5/8

(29)

73.5 to 

78.4

54 to 58

(750 to 

800)

4-1. PURGING PROCEDURES AND LEAK TEST

1) Remove service port cap of stop valve on the side of the outdoor unit gas pipe.
2) Connect gauge manifold valve and vacuum pump to service port of stop valve on the 

gas pipe side of the outdoor unit.

3) Run the vacuum pump 15 minutes or more.
4) Check the vacuum with the gauge manifold valve, then close it and shut off the vacuum 

pump.

5) Leave as it is for one or two minutes. Make sure pointer gauge manifold valve remains 

LQ WKH VDPH SRVLWLRQ &RQ¿UP WKDW SUHVVXUH JDXJH VKRZV ± 03D >*DXJH@ ±
LQ+J>±PP+J@

6) Quickly remove gauge manifold valve from service port of stop valve.
7) After refrigerant pipes are connected and evacuated, fully open all stop valves on both 

sides of gas pipe and liquid pipe. Operating the unit without fully opening the valves 
lowers the performance and causes problems.

8) Refer to 1-3. SPECIFICATIONS, and charge the prescribed amount of refrigerant if 

needed. Be sure to charge slowly with liquid refrigerant. Otherwise, composition of the 
refrigerant in the system may be changed and affect performance of the air conditioner.

9) Tighten cap of service port.
10) Conduct a leak test

Stop valve for 
GAS

Stop valve cap
(Torque 19.6 to 
29.4 N•m, 200 

WRNJIƒFP

Vacuum pump (or the vacuum 
pump with the function to 

SUHYHQWWKHEDFNÀRZ

Gauge manifold valve 
(for R410A)

Compound pressure gauge 
(for R410A)

±03D
±LQ+J
>±PP+J@

Handle
Low

Handle High

Adapter for pre-
venting the back 

ÀRZ

Charge hose 
(for R410A)

*Close

*Open

Hexagonal wrench

Precautions when using the control valve When attaching the control valve 

to the service port, valve core may 
deform or loosen if excess pressure 
is applied. This may cause gas leak.

Service port

Charge hose 

Body

Close

Open

Control valve

A

When attaching the control valve to 
the service port, make sure that the 
valve core is in closed position, and 
then tighten part A. Do not tighten 
part A or turn the body when valve 
core is in open position.

Service port cap
(Torque 13.7 to 
17.7 N•m, 140 to 
180 kgf•cm)

*4 to 5 turns

Stop valve 
for LIQUID

4. PURGING PROCEDURES, LEAK TEST, AND TEST RUN

Pressure gauge
(for R410A)

Uneven Burred

 WARNING

When installing the unit, securely connect the refrigerant pipes before starting the 
compressor.

Содержание MSZ-D30NA

Страница 1: ... is dust blockage or loose parts on the power supply plug or the outlet it could FDXVH HOHFWULF VKRFN RU UH I ORRVH SDUWV DUH IRXQG RQ WKH SRZHU VXSSO SOXJ UHSODFH LW N Securely attach the electrical cover to the indoor unit and the service panel to the outdoor unit If the electrical cover of the indoor unit and or the service panel of the outdoor unit are QRW DWWDFKHG VHFXUHO GXVW ZDWHU HWF FRXOG...

Страница 2: ...oom On a rigid wall to reduce the possibility of vibration Where it is not exposed to direct sunlight Where it can be easily drained At a distance 3 ft 1 m or more away from a TV and radio Operation of the air conditioner may interfere with radio or TV reception An amplifier may be re quired for the affected device In a place as far away as possible from fluorescent and incandescent lights so the ...

Страница 3: ...Please leave the space as shown in the picture for maintenance usage After the leak test apply insulating mate rial tightly so that there is no gap Indoor unit Wall hole sleeve C Cut off the extra length Pipe attach ment strap E Use the wall hole sleeve C to prevent indoor out door connecting wire A from contacting metal parts in the wall and to protect the wiring from rodents Wall hole cover D Se...

Страница 4: ...appear less than 1 3 16 in 30 mm outside Fig 2 9 Process the end of ground wire Fig 3 Connect it to the ground terminal of electrical parts box 10 Process the end of indoor outdoor unit connecting wire A Fig 3 Attach it to the terminal block Be careful not to make mis wiring Attach the wire to the terminal block securely so that its core cannot be seen and no external force affects the connecting ...

Страница 5: ...nit Fig 4 Check if the hose is hooked securely to the projection of its inserting part at the drain pan 6 Insert the drain hose into wall hole sleeve C and attach the upper part of indoor unit onto the installation plate 1 Then shift the indoor unit completely to the left to make placing the piping in the back of the unit easier 7 Cut out two pieces of cardboard from the shipping box use any two p...

Страница 6: ...pplied drain hose I Fig 2 When connecting the drain hose to a hard vinyl chloride pipe be sure to insert it securely into the pipe Fig 3 Do not make drain piping as shown below Do not raise Accumulated drain water Air Waving Water leakage Water leakage Water leakage Tip of drain hose dipped in water Ditch At least 1 31 32 in 50 mm gap Downward slope Drain hose Soft hose I D 19 32 in 15 mm Drain ho...

Страница 7: ...140 to 180 ø 3 8 9 52 3 8 22 34 3 to 41 2 25 to 30 350 to 420 ø 1 2 12 7 1 2 26 0 08 to 0 10 2 0 to 2 5 49 0 to 56 4 36 to 42 500 to 575 ø 5 8 15 88 5 8 29 73 5 to 78 4 54 to 58 750 to 800 4 1 PURGING PROCEDURES AND LEAK TEST 1 Remove service port cap of stop valve on the side of the outdoor unit gas pipe 2 Connect gauge manifold valve and vacuum pump to service port of stop valve on the gas pipe ...

Страница 8: ...ort of the stop valve on the gas pipe side of the outdoor unit 2 Fully close the stop valve on the liquid pipe side of the outdoor unit 3 Close the stop valve on the gas pipe side of the outdoor unit almost completely so that it can be easily closed fully when the pressure gauge shows 0 MPa Gauge 0 lbf in 2 0 kgf cm2 4 Start the emergency COOL operation To start the emergency operation in COOL mod...

Отзывы: