Outdoor unit installation

2-13/16 in. (70 

mm) or more/ 

5-1/8 in. (130 mm) 

or more for left and 

left back piping 

(using spacer)

1-4. INSTALLATION DIAGRAM

ACCESSORIES

Check the following parts before installation.
<Indoor unit>

(1) Installation plate

1

(2)

Attachment screws for the installa-
tion plate 
4 × 25 mm

7

(3) Remote controller holder

1

(4)

Screws for the remote controller 
holder
3.5 × 16 mm (Black)

2

(5) Battery (AAA) for (6)

2

(6) Wireless remote controller

1

(7)

Felt tape 
(For left or left-rear piping)

2

(8)

$LUFOHDQLQJ¿OWHU

2

(9) Charge nut

1

(10) L-joint

1

FIELD-SUPPLIED PARTS

(A)

Indoor/outdoor unit connecting wire *

1

(B)

Extension pipe

1

(C)

Wall hole sleeve

1

(D)

Wall hole cover

1

(E)

Pipe attachment strap

2 to 5

(F)

Screw for (E) 4 × 20 mm

2 to 5

(G)

Piping tape

1

(H)

Putty

1

(I)

Drain hose 
(or soft PVC hose, 19/32 in. [15 
mm] inner diameter or hard PVC 
pipe VP16)

1

(J)

Refrigerant oil

1

(K)

Power supply cord *

1

Units should be installed by licensed contractor 
according to local code requirements.

* Note:

Place indoor/outdoor unit connecting wire (A) 
and power supply cord (K) at least 3 ft. (1 m) 
away from the TV antenna wire.

Unit: inch

Unit: mm

4-11/16 in. 

(120 mm) 

or more

Space for indoor unit working

Please leave the space as shown in the 
picture for maintenance usage. 

After the leak test, apply insulating mate-

rial tightly so that there is no gap.

Indoor unit

Wall hole 
sleeve (C)

Cut off the 
extra length.

Pipe attach-
ment strap 
(E)

Use the wall hole sleeve 
(C) to prevent indoor/out-
door connecting wire (A) 
from contacting metal 
parts in the wall and to 
protect the wiring from 
rodents.

Wall hole cover (D)

Seal the wall hole 

gap with putty (H).

Attach the pipe to 

wall with pipe at-
tachment strap (E).

Attachment screw (F)

33-1/16

14-3/16

19-11/16

Air inlet

3-15/16

15-14/32

13

Air outlet

4-3/8 x 13/16 slot

1-18/32

40

840

100

500

Air inlet

392

330

360

Air outlet

4-10 x 21 slot

When the piping is to be attached to a wall 

comprised of tin plate or metal netting, use 
chemically treated wooden piece 25/32 in. 
(20 mm) or thicker between the wall and 
the piping, or wrap insulation vinyl tape 7 
to 8 turns around the piping.
To use existing piping, perform COOL 
operation for 30 minutes and pump down 
before removing the old air conditioner. 

5HPDNHÀDUHDFFRUGLQJWRWKHGLPHQVLRQ

for new refrigerant.

5/16 in. (7 mm)  or more

20 in. (500 mm)
or more

4 in.

(100 mm)

or more

4 in.

(100 mm)

or more

14 in.

(350 mm)

or more

20 in. 

(500 mm)

or more

Note:

Do not 
obstruct
the air 
outlet.

Indoor unit

Installation

plate

Space

9-27/32 in. (250

 

mm) or more

4 in. (100 mm)

 or more

8-11/16 in. 
(220 mm) 

or more

Содержание MSZ-D30NA

Страница 1: ... is dust blockage or loose parts on the power supply plug or the outlet it could FDXVH HOHFWULF VKRFN RU UH I ORRVH SDUWV DUH IRXQG RQ WKH SRZHU VXSSO SOXJ UHSODFH LW N Securely attach the electrical cover to the indoor unit and the service panel to the outdoor unit If the electrical cover of the indoor unit and or the service panel of the outdoor unit are QRW DWWDFKHG VHFXUHO GXVW ZDWHU HWF FRXOG...

Страница 2: ...oom On a rigid wall to reduce the possibility of vibration Where it is not exposed to direct sunlight Where it can be easily drained At a distance 3 ft 1 m or more away from a TV and radio Operation of the air conditioner may interfere with radio or TV reception An amplifier may be re quired for the affected device In a place as far away as possible from fluorescent and incandescent lights so the ...

Страница 3: ...Please leave the space as shown in the picture for maintenance usage After the leak test apply insulating mate rial tightly so that there is no gap Indoor unit Wall hole sleeve C Cut off the extra length Pipe attach ment strap E Use the wall hole sleeve C to prevent indoor out door connecting wire A from contacting metal parts in the wall and to protect the wiring from rodents Wall hole cover D Se...

Страница 4: ...appear less than 1 3 16 in 30 mm outside Fig 2 9 Process the end of ground wire Fig 3 Connect it to the ground terminal of electrical parts box 10 Process the end of indoor outdoor unit connecting wire A Fig 3 Attach it to the terminal block Be careful not to make mis wiring Attach the wire to the terminal block securely so that its core cannot be seen and no external force affects the connecting ...

Страница 5: ...nit Fig 4 Check if the hose is hooked securely to the projection of its inserting part at the drain pan 6 Insert the drain hose into wall hole sleeve C and attach the upper part of indoor unit onto the installation plate 1 Then shift the indoor unit completely to the left to make placing the piping in the back of the unit easier 7 Cut out two pieces of cardboard from the shipping box use any two p...

Страница 6: ...pplied drain hose I Fig 2 When connecting the drain hose to a hard vinyl chloride pipe be sure to insert it securely into the pipe Fig 3 Do not make drain piping as shown below Do not raise Accumulated drain water Air Waving Water leakage Water leakage Water leakage Tip of drain hose dipped in water Ditch At least 1 31 32 in 50 mm gap Downward slope Drain hose Soft hose I D 19 32 in 15 mm Drain ho...

Страница 7: ...140 to 180 ø 3 8 9 52 3 8 22 34 3 to 41 2 25 to 30 350 to 420 ø 1 2 12 7 1 2 26 0 08 to 0 10 2 0 to 2 5 49 0 to 56 4 36 to 42 500 to 575 ø 5 8 15 88 5 8 29 73 5 to 78 4 54 to 58 750 to 800 4 1 PURGING PROCEDURES AND LEAK TEST 1 Remove service port cap of stop valve on the side of the outdoor unit gas pipe 2 Connect gauge manifold valve and vacuum pump to service port of stop valve on the gas pipe ...

Страница 8: ...ort of the stop valve on the gas pipe side of the outdoor unit 2 Fully close the stop valve on the liquid pipe side of the outdoor unit 3 Close the stop valve on the gas pipe side of the outdoor unit almost completely so that it can be easily closed fully when the pressure gauge shows 0 MPa Gauge 0 lbf in 2 0 kgf cm2 4 Start the emergency COOL operation To start the emergency operation in COOL mod...

Отзывы: