79
8
GR
TR
中
8. À·›ıÚÈ· ηψ‰›ˆÛË (¶ÚԉȷÁڷʤ˜ ËÏÂÎÙÚÈÎÒÓ Î·Ïˆ‰›ˆÓ)
8. Alan elektrik kablo ba¤lant›lar› (Elektrik kablo ba¤lant› spesifikasyonlar›)
ªÔÓ٤Ϸ
∏ÏÂÎÙÚÈ΋ ·ÚÔ¯‹ ÂÛˆÙÂÚÈ΋˜ ÌÔÓ¿‰·˜
∏ÏÂÎÙÚÈ΋ ·ÚÔ¯‹
º¿ÛË
™˘¯ÓfiÙËÙ· & ∆¿ÛË
πηÓfiÙËÙ· ÂÈÛ·ÁˆÁ‹˜/
∂ÛˆÙÂÚÈ΋ ÌÔÓ¿‰· (A)
∫ÂÓÙÚÈÎfi˜ ‰È·ÎfiÙ˘/ ∞ÛÊ¿ÏÂÈ·
∂͈ÙÂÚÈ΋ ÌÔÓ¿‰· (A)
∂ÛˆÙÂÚÈ΋ ÌÔÓ¿‰·
∫·Ïˆ‰›ˆÛË ¡Ô.
∏ÏÂÎÙÚÈ΋ ·ÚÔ¯‹
ª¤ÁÂıÔ˜ ¯ÈÏ.
2
∂͈ÙÂÚÈ΋ ÌÔÓ¿‰·
∫·Ïˆ‰›ˆÛË ¡Ô.
∏ÏÂÎÙÚÈ΋ ·ÚÔ¯‹
ª¤ÁÂıÔ˜ ¯ÈÏ.
2
™‡Ó‰ÂÛË ÂÛˆÙÂÚÈ΋˜/Â͈ÙÂÚÈ΋˜ ÌÔÓ¿‰·˜
∫·Ïˆ‰›ˆÛË ¡Ô.
×
̤ÁÂıÔ˜ ¯ÈÏ. (¯ÈÏ.
2
)
∆ÈÌ‹ ΢ÎÏÒÌ·ÙÔ˜ ÂϤÁ¯Ô˘
Modeller
‹ç ünite güç kayna¤›
Güç kayna¤›
Faz
Frekans ve Voltaj
Girifl kapasitesi
‹ç ünite (A)
Ana flalter/sigorta
D›fl ünite (A)
‹ç ünite
Kablo No.
Güç kayna¤›
Çap mm
2
D›fl ünite
Kablo No.
Güç kayna¤›
Çap mm
2
‹ç ünite/D›fl ünite Ba¤lant›
Kablosu No.
×
Çap mm (mm
2
)
Kontrol devresi de¤eri
8.
PK-2.5FLA
PK-3FLA
PK-4FLSA
PK-4FLSA
PK-3FLA
PK-4FLSA
~ (ªÔÓ‹), 50 Hz, 220 - 240V ‹ 60 Hz, 220V
~ (ªÔÓ‹)
3 ~ (3ph)
3N ~ (3 Ê¿ÛÂȘ, 4 Û‡ÚÌ·Ù·)
50 Hz, 220 - 240V ‹ 60 Hz, 220V
60 Hz, 220V
50 Hz, 380/220 - 415/240V
16/16
16/16
16/16
16/16
16/16
16/16
32/25
32/25
32/32
25/25
16/16
16/16
3
3
3
3
3
3
1,5
1,5
1,5
1,5
1,5
1,5
3
3
3
4
5
5
4
4
4
2,5
1,5
1,5
2
×
0,8 (0,5) ‹ K·ÏÒ‰ÈÔ 2C
×
(0,3), (¯ˆÚ›˜ ÔÏÈÎfiÙËÙ·)
CC12V
∫·Ïˆ‰›ˆÛË
PK-2.5FLA
PK-3FLA
PK-4FLSA
PK-4FLSA
PK-3FLA
PK-4FLSA
~ (Tek), 50 Hz, 220 - 240V veya 60 Hz, 220V
~ (Tek)
3 ~ (3ph)
3N ~ (3 faz, 4 tel)
50 Hz, 220 - 240V veya 60 Hz, 220V
60 Hz, 220V
50 Hz, 380/220 - 415/240V
16/16
16/16
16/16
16/16
16/16
16/16
32/25
32/25
32/32
25/25
16/16
16/16
3
3
3
3
3
3
1,5
1,5
1,5
1,5
1,5
1,5
3
3
3
4
5
5
4
4
4
2,5
1,5
1,5
2
×
0,8 (0,5) veya kablo 2C
×
(0,3), (Polarlanmam›fl)
DC12 V
Kablo ba¤lant›lar›
™ËÌÂÈÒÛÂȘ:
1. ŸÙ·Ó οÓÂÙ ÙËÓ Î·Ïˆ‰›ˆÛË Î·È ÙȘ Û˘Ó‰¤ÛÂȘ Ú¤ÂÈ Ó· Ï·Ì‚¿ÓÂÙ ˘fi„Ë Û·˜ ÙȘ Û˘Óı‹Î˜ ÙÔ˘ ÂÚÈ‚¿ÏÏÔÓÙÔ˜ (ıÂÚÌÔÎÚ·Û›· ÂÚÈ‚¿ÏÏÔÓÙÔ˜, ¿ÌÂÛÔ ËÏÈ·Îfi
ʈ˜, ÓÂÚfi ‚ÚÔ¯‹˜, ÎÏ.).
2. ∆Ô Ì¤ÁÂıÔ˜ ÙˆÓ Î·Ïˆ‰›ˆÓ Â›Ó·È Ë ÂÏ¿¯ÈÛÙË ÙÈÌ‹ ÁÈ· ÌÂÙ·ÏÏÈÎfi ËÏÂÎÙÚÈÎfi ηÏÒ‰ÈÔ ÙÔ ÔÔ›Ô Ê¤ÚÂÈ ÚÔÛٷ٢ÙÈÎfi ÂÚ›‚ÏËÌ·. °È· Ó’·ÓÙÈÌÂÙˆ›˙ÔÓÙ·È ÔÈ ÙÒÛÂȘ
ÛÙËÓ Ù¿ÛË ÙÔ˘ Ú‡̷ÙÔ˜, ÙÔ ËÏÂÎÙÚÈÎfi ηÏÒ‰ÈÔ Ú¤ÂÈ Ó· Â›Ó·È Î·Ù¿ ¤Ó· ‚·ıÌfi ¯ÔÓÙÚ‡ÙÂÚÔ.
3. ∏ ‰‡Ó‰ÂÛË ÙÔ˘ Û‡ÚÌ·ÙÔ˜ Á›ˆÛ˘ Á›ÓÂÙ·È ÙfiÛÔ Ì ÙËÓ ÂÛˆÙÂÚÈ΋ fiÛÔ Î·È Ì ÙËÓ Â͈ÙÂÚÈ΋ ÌÔÓ¿‰·.
4. √ ›Ó·Î·˜ ·˘Ùfi˜ ‰Â›¯ÓÂÈ ·Ú¿‰ÂÈÁÌ· ˘·›ıÚÈ·˜ ËÏÂÎÙÚÈ΋˜ ηψ‰›ˆÛ˘. √È ÏÂÙÔ̤ÚÂȘ Ú¤ÂÈ Ó· ‚·Û›˙ÔÓÙ·È ÛÙ· Ù¯ÓÈο ÚfiÙ˘· Ô˘ ÈÛ¯‡Ô˘Ó.
Notlar:
1. Kablolar› döflemeye ve ba¤lant›lar› yapmaya bafllarken çevre koflullar›n› (çevre s›cakl›¤›, direkt günefl ›fl›¤›, ya¤mur suyu, vb.) dikkate al›n›z.
2. Kablo kal›nl›¤› rakamlar›, metal kablo borusuyla döfleme için asgari de¤erlerdir. Elektrik kordonunun kal›nl›¤›, voltaj düflmeleri dikkate al›narak 1 mertebe daha
kal›n olmal›d›r.
3. Toprak kablosu hem iç üniteye hem de d›fl üniteye ba¤lan›r.
4. Bu tabloda alan elektrik kablo düzeninin bir örne¤i görülmektedir. Detaylar, uygun teknik standartlara göre yap›lmal›d›r.