3.2. Initial setting
Fig. 3-1
Fig. 3-2
A
A
D
E
C
B
7
9
1
4
2
3
6
5
8
F
The following settings can be made in the initial setting mode.
Item
Setting
Fig. 3-1, 3-2
Temperature unit
ºC/ºF
A
Time display
12-hour format/24-hour format
B
AUTO mode
Single set point/Dual set point
C
Pair No.
0–3
D
Backlight
On/Off
E
1) Switching to the initial setting mode
1. Press the
button
1
to stop the air conditioner.
• If the weekly timer is enabled, press the
button
9
to disable the
timer. (
F
disappears.)
2. Press the
button
2
.
• The Function setting screen will be displayed and the function No.
A
will blink. (Fig. 3-1)
• Press the
button
4
to change the function No.
3. Check that function No. “1” is displayed, and then press the
button
3
.
• The display setting screen will be displayed. (Fig. 3-2)
2) Changing the temperature unit
A
(Fig. 3-2)
Press the
button
5
.
• Each time the
button
5
is pressed, the setting switches between
and .
: The temperature is displayed in degrees Celsius.
:
The temperature is displayed in degrees Fahrenheit.
3) Changing the time display
B
(Fig. 3-2)
Press the
button
6
.
• Each time the
button
6
is pressed, the setting switches between
and
.
: The time is displayed in the 12-hour format.
: The time is displayed in the 24-hour format.
4) Changing the AUTO mode
C
(Fig. 3-2)
Press the
button
7
.
• Each time the
button
7
is pressed, the setting switches between
and .
: The AUTO mode operates as the usual automatic mode.
: The AUTO mode operates using dual set points.
* The AUTO (dual set point) mode cannot be used depending on the
models of the connected indoor and outdoor units.
5) Changing the pair No.
D
(Fig. 3-2)
Press the
button
4
.
• Each time the
button
4
is pressed, the pair No. 0–3 changes.
6) Changing the backlight setting
E
(Fig. 3-2)
Press the
button
8
.
• Each time the
button
8
is pressed, the setting switches between
and
.
: The backlight comes on when a button is pressed.
: The backlight does not come on when a button is pressed.
7) Completing the settings
Press the
button
3
.
• The function No.
A
blinks. (Fig. 3-1)
Press the
button
2
.
• The remote controller exits the initial setting mode. (The air conditioner
operation is stopped.)
• The transmission mark appears each time a signal is transmitted.
• The indoor unit beeps to confi rm that the signal transmitted from the
wireless remote controller has been received by the receiver on the
indoor unit. If the indoor unit does not beep, transmit the signal again.
WIRELESS REMOTE CONTROLLER
3
.Before Operation
[P
AR-SL100A-E
]
D-69
WIRELESS REMOTE CONTROLLER