Component/
Part Name
Check Method and Criterion
Part Mounted
Position
41
Vegetable
compartment
heater
Water supply
pipe heater
At the bottom of
the vegetable
compartment
(inside poly-
urethane foam)
The connectors
are in the con-
nector box on
the ceiling of
the vegetable
compartment.
Under the mount-
ing position
of water tank
(inside polyure-
thane foam)
The connec-
tor is in the
left back of
the refrigerator
compartment.
Measure the resistance with a tester. (Ambient temperature: Room temperature)
Measure the resistance with a tester. (Ambient temperature: Room temperature)
Rated input
W
6.0
Operation method
The heater turns on when vegetable compartment thermistor
has reached a lower temperature than the set temperature for
vegetable compartment.
Normal
Abnormal (faulty)
2.0 k (Approx.)
Open circuit (
)
Rated input
W
7.0
Operation method
The heater turns on with the energization rate adjusted accord-
ing to each setting for the ice making, refrigerator and freezer
compartment.
Normal
Abnormal (faulty)
8.2 k (Approx.)
Open circuit (
)
Drain pipe heater
Near the bot-
tom of the drip
tray under the
evaporator in the
freezer compart-
ment
Measure the resistance with a tester. (Ambient temperature: Room temperature)
Rated input
W
7.0
Operation method
The heater is energized while defrosting.
(Defrosting is finished when the evaporator is 14±1.5 or more)
Normal
Abnormal (faulty)
8.2 k (Approx.)
Open circuit (
)
OAH162