20
6) Setting adjustment mode
The temperature of each compartment and the energization rate of the heaters can be adjusted by touching the
buttons on the operation panel. There are two modes. In the “setting adjustment mode”, the setting temperature of
the compartment is adjustable. In the “heater energization rate adjustment mode”, you can adjust the energization
rate of the pipe heater. Start the setting adjustment mode first to operate these modes.
Setting
With the ice making compartment door open, touch
and
simultaneously for 3 seconds until 2 short beeps sound.
blinks.
With the ice making compartment door open, touch
to select the blinking
.
With the ice making compartment door open, touch
for 3 seconds until 2 short beeps sound.
The set temperature adjustment mode has started. This mode continues operating even if the door gets closed.
Display during the set temperature adjustment mode
During set temperature adjustment mode,
blinks and
and
are lit.
a) Compartment serial number
Each serial number is assigned to each compartment that will be used in the set temperature adjustment mode besides
damper operation mode and thermistor temperature check mode.
The values (8, 4, 2, and 1) are assigned to each indicator. The sum of the values corresponding to the lit indicators is the
compartment serial number.
Display
Corresponding values
8
4
2
1
b) Set temperature adjustment level
3 indicators of
,
and
display the adjustment level of the setting temperature.
(2) Adjusting the set temperature
i. Select the compartment with
.
Each touch of
changes the compartment of which set temperature will be adjusted along with a short beep.
Each compartment will be displayed using the serial numbers (1: Refrigerator compartment~ 6: Freezer
compartment) in numeric order repeatedly.
a) Compartment
serial
number
b) Adjustment level
“–”
signs
b) Set temperature
adjustment
level
Blinking
Mode display
(Not lit): Setting adjustment mode
“
” “
” Lit
Switching the mode
Select the mode to adjust with
.
Each touch of
switches the mode between “setting adjustment mode” and “heater energization rate adjustment mode”
along with a short beep.
display
Setting adjustment mode
Not lit
Setting adjustment mode
Adjusts the temperature of each compartment.
Lit
Heater energization rate adjust-
ment mode
Adjusts the heater energization rate of the
pipe heater.
Setting adjustment mode
(1) Display
Serial number
Assigned compartment
Set temperature adjustment mode
1
Refrigerator compartment
2
Chilled
3
Ice making compartment
4
Versa compartment
5
Vegetable compartment
6
Freezer compartment
/ : SW operation is effective/ineffective
Chilled: For lower case
OAH162