4. PARAMETERS
4 - 30
4.3 Software limit
The limit stop with the software limit ([Pr. PT15] to [Pr. PT18]) is the same as the motion of the stroke end.
Exceeding a setting range will stop and servo-lock the shaft. This will be enabled at power-on and will be
disabled in the profile velocity mode, profile torque mode, and homing mode. Setting a same value to
"Software limit +" and "Software limit -" will disable this function. Setting a larger value to "Software limit -"
than "Software limit +" will disable this function.
Current position
Travel
impossible
Inhibited range
Software limit
Movable range
Travel possible
4.4 How to set the electronic gear
4.4.1 Electronic gear setting for the profile mode
(1) Setting [pulse] with "Position data unit" of [Pr. PT01]
Adjust [Pr. PA06] and [Pr. PA07] to match the servo amplifier setting with the travel distance of the
machine.
Travel distance
CDV
CMX
Deviation counter
+
-
Electronic gear
([Pr. PA06]/[Pr. PA07])
Servo motor
Encoder
M
P
t
: Servo motor encoder resolution: 131072 [pulse/rev]
ΔS: Travel distance per servo motor revolution [pulse/rev]
CMX/CDV = P
t
/ΔS
The following setting example explains how to calculate the electronic gear.
POINT
To calculate the electronic gear, the following specification symbols are
required.
Pb: Ball screw lead [mm]
1/n: Reduction ratio
P
t
: Servo motor encoder resolution [pulse/rev]
ΔS: Travel distance per servo motor revolution [mm/rev]