2. SIGNALS AND WIRING
2 - 5
2.3 Signal (device) explanations
For details of the devices and I/O interfaces (symbols in I/O division column in the table) not described in the
table, refer to sections 3.5 and 3.9 in "MR-JE-_C Servo Amplifier Instruction Manual".
Device
Symbol Connector
pin No.
Function and application
I/O
division
Proximity dog
DOG
Turning off DOG will detect a proximity dog. The polarity for dog detection can
be changed with [Pr. PT29].
DI-1
[Pr. PT29]
Polarity for proximity dog
detection
_ _ _ 0
Detection with off
_ _ _ 1
Detection with on
Touch probe 1
TPR1
CN3-6 The touch probe function that executes current position latch by sensor input
can be used. For details of the touch probe function, refer to "MR-JE-_C Servo
Amplifier Instruction Manual (Network)".
DI-1
2.4 Power-on sequence
POINT
The output signal, etc. may be unstable at power-on.
(1) Power-on procedure
1) Always wire the power supply as shown in above section 3.1 of "MR-JE-_C Servo Amplifier
Instruction Manual" using the magnetic contactor with the power supply (L1/L2/L3). Configure up
an external sequence to switch off the magnetic contactor as soon as an alarm occurs.
2) The servo amplifier receives the servo-on command in 3 s to 4 s + network initial communication
time after the power supply is switched on.
(Refer to (2) in this section.)
(2) Timing chart
(3 s to 4 s + network initial communication time)
95 ms
10 ms
95 ms
Servo-on command accepted
Base circuit
Servo-on command
(from controller)
Power supply
ON
OFF
ON
OFF
ON
OFF