4. PARAMETERS
4 - 11
4.1.7 Positioning control parameters ([Pr. PT_ _ ])
No.
Symbol
Name
Initial
value
Unit
Detailed
explanation
PT01
*CTY
Command mode selection
0300h
Section 4.2.5
PT02
For manufacturer setting
0001h
PT03
*FTY
Feeding function selection
0000h
Section 4.2.5
PT04
For manufacturer setting
0000h
PT05
ZRF
Home position return speed
100.00
[r/min]
Section 4.2.5
PT06
CRF
Creep speed
10.00
[r/min]
PT07
ZST
Home position shift distance
0
10
-3
[degree]/
[pulse]
PT08
For manufacturer setting
0
PT09
DCT
Travel distance after proximity dog
0
10
-3
[degree]/
[pulse]
Section 4.2.5
PT10
ZTM
Stopper type home position return stopper time
100
[ms]
PT11
ZTT
Stopper type home position return torque limit value
15.0
[%]
PT12
For manufacturer setting
0
PT13
100.00
PT14
0
PT15
LMPL Software limit +
0000h 10
-3
[degree]/
[pulse]
Section 4.2.5
PT16
LMPH
0000h 10
-3
[degree]/
[pulse]
PT17
LMNL Software limit -
0000h 10
-3
[degree]/
[pulse]
PT18
LMNH
0000h 10
-3
[degree]/
[pulse]
PT19
For manufacturer setting
0000h
PT20
0000h
PT21
0000h
PT22
0000h
PT23
0
PT24
0
PT25
0
PT26
*TOP2 Function selection T-2
0000h
Section 4.2.5
PT27
For manufacturer setting
0000h
PT28
8
PT29
*TOP3 Function selection T-3
0000h
Section 4.2.5
PT30
For manufacturer setting
0000h
PT31
0000h
PT32
0000h
PT33
0000h
PT34
0000h
PT35
0000h
PT36
0000h
PT37
10
PT38
0000h
PT39
100
PT40
0
PT41
ORP
Home position return inhibit function selection
0000h
Section 4.2.5
PT42
For manufacturer setting
0
PT43
0
PT44
0000h
Содержание MELSERVO-JE
Страница 15: ...1 FUNCTIONS AND CONFIGURATION 1 4 MEMO ...
Страница 21: ...2 SIGNALS AND WIRING 2 6 MEMO ...
Страница 57: ...4 PARAMETERS 4 34 MEMO ...
Страница 109: ...6 SERVO MOTOR DRIVING 6 44 MEMO ...
Страница 111: ...7 APPLICATION OF FUNCTIONS 7 2 MEMO ...
Страница 113: ...MEMO ...