2.13 M+FX5PG_StartAddressOffsetPositioning
Processing
• By turning i_bEN (Execution command) ON, the settings are made to start the following axis after the preceding axis has
moved the set movement amount.
• When i_bEN (Execution command) turns ON, the following axis will move only when all of the following conditions are
satisfied. If the conditions are not satisfied, o_bErr (Error completion) turns ON and the processing of this FB is
interrupted. In addition, error code 200 (hexadecimal) is stored in o_uErrId (Error code). For details on the error code,
refer to the
Page 46 Error code. (The conditions are Positioning module ready signal (Md.140: Module status.b0):
ON, Positioning start signal (Cd.184: Positioning start signal): OFF, Start complete signal (Md.31: Status.b14): OFF,
BUSY signal (Md.141: BUSY.b0, b1): OFF)
• If the set value of the preceding axis is out of the range, o_bErr (Error completion) turns ON, and processing of this FB is
interrupted. In addition, error code 103 (hexadecimal) is stored in o_uErrId (Error code). For details on the error code,
refer to the
• If the set value of the following axis is out of the range, o_bErr (Error completion) turns ON, and processing of this FB is
interrupted. In addition, error code 104 (hexadecimal) is stored in o_uErrId (Error code). For details on the error code,
refer to the
• If the same axis number is set for the preceding axis and following axis, o_bErr (Error completion) turns ON, and
processing of this FB is interrupted. In addition, error code 105 (hexadecimal) is stored in o_uErrId (Error code). For
details on the error code, refer to the
• If the set value of the start block is out of the range, o_bErr (Error completion) turns ON, and processing of this FB is
interrupted. In addition, error code 106 (hexadecimal) is stored in o_uErrId (Error code). For details on the error code,
refer to the
• If the set value of the point is out of the range, o_bErr (Error completion) turns ON, and processing of this FB is
interrupted. In addition, error code 107 (hexadecimal) is stored in o_uErrId (Error code). For details on the error code,
refer to the
• If the set value of the start data No. is out of the range, o_bErr (Error completion) turns ON, and processing of this FB is
interrupted. In addition, error code 108 (hexadecimal) is stored in o_uErrId (Error code). For details on the error code,
refer to the
• If the set value of the condition data No. is out of the range, o_bErr (Error completion) turns ON, and processing of this FB
is interrupted. In addition, error code 109 (hexadecimal) is stored in o_uErrId (Error code). For details on the error code,
refer to the
• If the set value of the offset address is out of the range (only when preceding axis Pr. 1: unit setting is 2: degree), or when
the value obtained by adding the preceding axis feed current value to the offset address is out of the range, o_bErr (Error
completion) turns ON, and processing of this FB is interrupted. In addition, error code 10A (hexadecimal) is stored in
o_uErrId (Error code). For details on the error code, refer to the
FB compilation method
Macro type
FB operation
Pulsed execution (multiple scan execution type)
Item
Description
Time
Position
When the offset address is a positive value.
When the offset address is a negative value.
Offset
address
Preceding axis
Following axis
Time
Position
Offset
address
Following axis
Preceding axis