![Mitsubishi Electric MELSEC iQ-F Скачать руководство пользователя страница 21](http://html.mh-extra.com/html/mitsubishi-electric/melsec-iq-f/melsec-iq-f_manual_239102021.webp)
2 POSITIONING MODULE FB
2.5 M+FX5PG_ChangeSpeed
19
2
FB details
Item
Description
Available device
Target module
FX5-20PG-P
Target CPU
FX5U CPU, FX5UC CPU
Engineering tool
GX Works3 Version 1.035M or later
Language
Ladder diagram
Number of basic steps
136 steps
The number of FB steps integrated in the program varies depending on the CPU module used, the input/output definition, and
the setting options of GX Works3. For the setting options of GX Works3, refer to
GX Works3 Operating Manual.
Processing
• By turning on i_bEN (Execution command), the speed used for the control is changed to a new speed.
• If the setting value of the target axis is out of the setting range, o_bErr (Error completion) turns on and the processing of this
FB is interrupted. In addition, the error code 100 (hexadecimal) is stored in o_uErrId (Error code). For the error code, refer to
FB compilation method
Macro type
FB operation
Pulse execution (multiple scan execution type)
Timing chart of I/O signals
[For normal completion]
[For error completion]
1
0
0
0
New Value
Present value
Cd.14: New speed value
Cd.15: Speed change request
i_bEN
o_bENO
o_bOK
o_bErr
o_uErrId
Error code
0
0
Present value
0
Cd.14: New speed value
Cd.15: Speed change request
i_bEN
o_bENO
o_bOK
o_bErr
o_uErrId