![Mitsubishi Electric MELSEC iQ-F Скачать руководство пользователя страница 36](http://html.mh-extra.com/html/mitsubishi-electric/melsec-iq-f/melsec-iq-f_manual_239102036.webp)
34
2 POSITIONING MODULE FB
2.10 M+FX5PG_InitializeParameter
2.10
M+FX5PG_InitializeParameter
Name
M+FX5PG_InitializeParameter
Overview
Labels
■
Input label
■
Output label
Item
Description
Overview
Initializes parameters.
Symbol
No.
Variable name
Name
Data type
Range
Description
(1)
i_bEN
Execution command
Bit
ON, OFF
ON: The FB is activated.
OFF: The FB is not activated.
(2)
i_stModule
Module label
Structure
The setting range
differs depending on
the module label.
Specifies the module label for the positioning module.
No.
Variable name
Name
Data type
Default value
Description
(3)
o_bENO
Execution status
Bit
OFF
ON: The execution command is ON.
OFF: The execution command is OFF.
(4)
o_bOK
Normal completion
Bit
OFF
When this label is ON, it indicates that parameter
initialization has been completed.
(5)
o_bErr
Error completion
Bit
OFF
Always OFF
(6)
o_uErrId
Error code
Word [Unsigned]
0
Always 0
(6)
(5)
(4)
M+FX5PG_InitializeParameter
(3)
(2)
(1)
o_uErrId
o_bErr
o_bOK
o_bENO
UW
B
B
B
DUT
B
:
:
:
:
:
:
i_stModule
i_bEN
Содержание MELSEC iQ-F
Страница 1: ...MELSEC iQ F FX5 Positioning Module Function Block Reference ...
Страница 2: ......
Страница 5: ...1 FUNCTION BLOCK FB LIST 3 1 MEMO ...
Страница 55: ...I 53 MEMO ...
Страница 57: ......