![Mitsubishi Electric MELSEC iQ-F Скачать руководство пользователя страница 23](http://html.mh-extra.com/html/mitsubishi-electric/melsec-iq-f/melsec-iq-f_manual_239102023.webp)
2 POSITIONING MODULE FB
2.6 M+FX5PG_ChangeAccDecTime
21
2
2.6
M+FX5PG_ChangeAccDecTime
Name
M+FX5PG_ChangeAccDecTime
Overview
Labels
■
Input label
■
Output label
Item
Description
Overview
Changes the acceleration/deceleration time during speed change.
Symbol
No.
Variable name
Name
Data type
Range
Description
(1)
i_bEN
Execution command
Bit
ON, OFF
ON: The FB is activated.
OFF: The FB is not activated.
(2)
i_stModule
Module label
Structure
The setting range
differs depending on
the module label.
Specifies the module label for the positioning module.
(3)
i_uAxis
Target axis
Word [Unsigned]
1 to 4
Specify the axis number.
The setting range varies according to the positioning
module in use.
(4)
i_bEnable
Acceleration/
deceleration time
change enabled flag
Bit
ON: Enabled
OFF: Disabled
Set this label to enable or disable the acceleration/
deceleration time change.
(5)
i_udNewAccTime
Cd.10: New
acceleration time
value
Double Word
[Unsigned]
0 to 8388608 ms
Set a new acceleration time.
When 0 is set, the acceleration time is not changed
after the speed is changed.
In this case, the operation is controlled at the previously
set acceleration time.
(6)
i_udNewDecTime
Cd.11: New
deceleration time
value
Double Word
[Unsigned]
0 to 8388608 ms
Set a new deceleration time.
When 0 is set, the deceleration time is not changed
after the speed is changed.
In this case, the operation is controlled at the previously
set deceleration time.
No.
Variable name
Name
Data type
Default value
Description
(7)
o_bENO
Execution status
Bit
OFF
ON: The execution command is ON.
OFF: The execution command is OFF.
(8)
o_bOK
Normal completion
Bit
OFF
When this label is ON, it indicates that setting the
acceleration/deceleration time change has been
completed.
(9)
o_bErr
Error completion
Bit
OFF
When this label is ON, it indicates that an error has
occurred in the FB.
(10)
o_uErrId
Error code
Word [Unsigned]
0
Stores the error code that occurred in the FB.
(10)
(9)
(8)
M+FX5PG_ChangeAccDecTime
(7)
(3)
(2)
(1)
o_uErrId
o_bErr
o_bOK
o_bENO
UW
B
B
B
UW
DUT
B
:
:
:
:
:
:
:
i_uAxis
(4)
B : i_bEnable
i_stModule
i_bEN
:
(5)
UD : i_udNewAccTime
(6)
UD : i_udNewDecTime
Содержание MELSEC iQ-F
Страница 1: ...MELSEC iQ F FX5 Positioning Module Function Block Reference ...
Страница 2: ......
Страница 5: ...1 FUNCTION BLOCK FB LIST 3 1 MEMO ...
Страница 55: ...I 53 MEMO ...
Страница 57: ......