2 POSITIONING MODULE FB
2.2 M+FX5PG_StartPositioning
FB details
Item
Description
Available device
Target module
FX5-20PG-P
Target CPU
FX5U CPU, FX5UC CPU
Engineering tool
GX Works3 Version 1.035M or later
Language
Ladder diagram
Number of basic steps
263 steps
The number of FB steps integrated in the program varies depending on the CPU module used, the input/output definition, and
the setting options of GX Works3. For the setting options of GX Works3, refer to
GX Works3 Operating Manual.
Processing
• By turning on i_bEN (Execution command), the control corresponding to i_uStartNo (Cd.3: Positioning start No.) is started.
• This FB is activated by turning on Positioning start signal (Cd.184: Positioning start signal).
• Only when the following conditions are satisfied, Positioning start signal (Cd.184: Positioning start signal) is turned on by
turning on i_bEN (Execution command). If any of the conditions is not satisfied, o_bErr (Error completion) turns on and the
processing of this FB is interrupted. In addition, the error code 200 (hexadecimal) is stored in o_uErrId (Error code). For the
error code, refer to
Page 11 Error code. (The conditions are Positioning module ready signal (Md.140: Module
status.b0): ON, Positioning start signal (Cd.184: Positioning start signal): OFF, Start complete signal (Md.31: Status.b14):
OFF, BUSY signal (Md.141: BUSY.b0, b1): OFF)
• When Start complete signal (Md.31: Status.b14) turns on or i_bEN (Execution command) is turned off, Positioning start
signal (Cd.184: Positioning start signal) is turned off.
• If the setting value of the target axis is out of the setting range, o_bErr (Error completion) turns on and the processing of this
FB is interrupted. In addition, the error code 100 (hexadecimal) is stored in o_uErrId (Error code). For the error code, refer to
• If the setting value of the positioning start No. is out of the setting range, o_bErr (Error completion) turns on and the
processing of this FB is interrupted. In addition, the error code 102 (hexadecimal) is stored in o_uErrId (Error code). For the
error code, refer to
FB compilation method
Macro type
FB operation
Pulsed execution (multiple scan execution type)
Timing chart of I/O signals
[For normal completion]
[For error completion]
0
Start No.
0
Cd.3: Positioning start No.
Cd.184: Positioning start signal
Start complete signal
(Md.31: Status.b14)
i_bEN
o_bENO
o_bOK
o_bErr
o_uErrId
0
0
Error code
0
Cd.3: Positioning start No.
Cd.184: Positioning start signal
Start complete signal
(Md.31: Status.b14)
o_bENO
o_bOK
o_bErr
o_uErrId
i_bEN