Introduction
Cautions on design
•
Install a safety circuit outside the PLC or the temperature control block FX
2N
-2LC so that
the entire system conservatively operates even if an abnormality occurs in the external
power supply or a failure occurs in the PLC or the FX
2N
-2LC.
If a safety circuit is installed inside the PLC, malfunction and erroneous output may
cause accidents.
1) Make sure to construct an emergency stop circuit, protection circuit or interlock circuit to
prevent damages of a machine, etc. outside the PLC or the FX
2N
-2LC.
2) If the PLC or the FX
2N
-2LC detects an abnormality such as a watch dog timer error or
input value error by the self-diagnosis function or when an abnormality occurs in the I/O
control area, etc. which cannot be detected by the CPU in the PLC, output control may
be disabled.
Design external circuits and structure so that the entire system conservatively operates
in such cases.
3) If a failure occurs in a relay, transistor, TRIAC, etc. in an output unit of the FX
2N
-2LC or
the PLC, outputs may keep ON or OFF.
For output signals which may lead to severe accidents, design external circuits and struc-
ture so that the entire system conservatively operates.
Cautions on installation
•
Use the unit in the environment for the general specifications described in the manual.
Never use the unit in a place with dusts, soot, conductive dusts, corrosive gas or flamma-
ble gas, place exposed to high temperature, dew condensation or rain and wind or place
exposed to vibration or impact.
If the unit is used in such a place, electrical shock, fire, malfunction, damages in the unit
or deterioration of the unit may be caused.
•
Never drop cutting chips or electric wire chips into the ventilation window of the FX
2N
-
2LC while drilling screw holes or wiring cables.
Such chips may cause fire, failure or malfunction.
•
After finishing installation, remove a dust preventing sheet adhered on the ventilation
window of the PC and the FX
2N
-2LC.
If the sheet remains attached, fire, failure or malfunction may be caused.
•
Securely connect cables such as extension cables and memory cassettes to specified
connectors.
Imperfect contact may cause malfunction.
Caution on disposal
•
When disposing of the unit, treat it as industrial waste.
FX2N-2LC Temperature Control Block
Содержание MELSEC FX2N-2LC
Страница 1: ...USER S MANUAL FX2N 2LC Temperature Control Block ...
Страница 4: ...FX2N 2LC Tempereture Control Block ii ...
Страница 6: ...FX2N 2LC Tempereture Control Block iv ...
Страница 12: ...FX2N 2LC Temperature Control Block Introduction 1 ...
Страница 16: ...FX2N 2LC Temperature Control Block Product Configuration 2 ...
Страница 22: ...FX2N 2LC Temperature Control Block Specifications 3 ...
Страница 28: ...FX2N 2LC Temperature Control Block Specifications 3 3 6 ...
Страница 30: ...FX2N 2LC Temperature Control Block Wiring 4 ...
Страница 34: ...FX2N 2LC Temperature Control Block Introduction of Functions 5 ...
Страница 44: ...FX2N 2LC Temperature Control Block Introduction of Functions 5 5 10 ...
Страница 46: ...FX2N 2LC Temperature Control Block Alarm 6 ...
Страница 52: ...FX2N 2LC Temperature Control Block Alarm 6 6 6 ...
Страница 54: ...FX2N 2LC Temperature Control Block Buffer Memory BFM 7 ...
Страница 84: ...FX2N 2LC Temperature Control Block Buffer Memory BFM 7 7 30 ...
Страница 86: ...FX2N 2LC Temperature Control Block Program Example 8 ...
Страница 94: ...FX2N 2LC Temperature Control Block Program Example 8 8 8 ...
Страница 96: ...FX2N 2LC Temperature Control Block Troubleshooting 9 ...