Chapter 2 Wiring and Connection
2-20
2-4-16 Connection of HC-MF(-UE) Series
2-4-17 Connection of HC-MF
□
-S15 Series
2-0.3
2
0.3m
With round crimp terminal with end insulator
1.25-2
Blue: B1, B2 24VDC with no polarity
U
BAT
9
Signal
LG
LG
MR
MD
2
5
1
Pin
6
4
3
10
7
8
P5 (+5V)
19
Signal
LG
LG
MRR
MDR
12
P5 (+5V)
P5 (+5V)
15
11
Pin
16
14
13
20
17
18
MDS-B-SVJ2-01 to 04
MDS-B-SVJ2-07
1
4
8
6
5
3
2
7
9
SD
9
Signal
MD
MR
MRR
MDR
BAT
P5 (+5V)
CONT
2
LG
5
1
Pin
6
4
3
7
8
V W
HC-MF053 (-UE), 13 (-UE)
Motor
Amplifier
HC-MF23 (-UE)
HC-MF43 (-UE)
HC-MF73 (-UE)
MDS-B-SVJ2-01
MDS-B-SVJ2-03
MDS-B-SVJ2-04
MDS-B-SVJ2-07
Motor and amplifier combinations
Power wire and grounding wire
(Refer to Chapter 7 for details on selecting the wire.)
Power supply lead
4-AWG19 0.3m
With round crimp terminal with
end insulator 1.25-4
Red : U phase, White :V phase,
Black : W phase
Yellow/Green : Grounding
Brake lead
Detector cable 0.3m
With connector
172161-9 (AMP)
Detector connector: CN2
Pin No.
No.1
No.10
No.11
No.20
Max. 50m
Option cable: MR-JHSCBL
□
M-H
(Refer to Chapter 6 for details on the
cable treatment)
Detector connector
172161-9
Option cable: MR-RMCBL
□
M
(Refer to Chapter 6 for details on the cable treatment)
U
BAT
9
Signal
LG
LG
MR
MD
2
5
1
Pin
6
4
3
10
7
8
P5 (+5V)
19
Signal
LG
LG
MRR
MDR
12
P5 (+5V)
P5 (+5V)
15
11
Pin
16
14
13
20
17
18
Pin No.
Detector connector: CN2
No.1
No.10
No.11
No.20
MDS-B-SVJ2-01 to 04
MDS-B-SVJ2-07
Max. 50m
V W
HC-MF13-S15
Motor Amplifier
HC-MF23-S15
HC-MF43-S15
HC-MF73-S15
MDS-B-SVJ2-01
MDS-B-SVJ2-03
MDS-B-SVJ2-04
MDS-B-SVJ2-07
Motor and amplifier combinations
Power wire and grounding wire
(Refer to Chapter 7 for details on selecting the wire.)
Detector lead 0.5m
With RM15WTP-10P
connector (Hirose)
SD
9
Signal
MD
MR
MRR
MDR
BAT
P5 (+5V)
CONT
2
LG
5
1
Pin
6
4
3
7
8
RM15WTP-10P
Detector connector
10
Power supply lead 0.5m
With RM15WTP-4P
connector (Hirose)
Power supply connector
RM15WTP-4P
Signal
Grounding
U
V
W
2
1
Pin
4
3
1
4
3
2
10
1
4
8
6
5
3
2
7
9
Содержание MELDAS MDS-B-SVJ2 Series
Страница 1: ......
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 46: ......
Страница 92: ......
Страница 108: ......
Страница 152: ......
Страница 186: ......
Страница 194: ......
Страница 218: ......
Страница 260: ......
Страница 282: ......
Страница 283: ...12 1 Chapter 12 Inspections 12 1 Inspections 12 2 12 2 Life parts 12 2 ...
Страница 294: ......
Страница 297: ......