![Mitsubishi Electric MELDAS MDS-B-SVJ2 Series Скачать руководство пользователя страница 100](http://html.mh-extra.com/html/mitsubishi-electric/meldas-mds-b-svj2-series/meldas-mds-b-svj2-series_specifications-and-instruction-manual_239059100.webp)
Chapter 4 Setup
4-8
(3) HC
R Series
Motor series name
HC
R-E42, -E33, HC
R-A47, -A42, -A33
ABS/INC
HC
R-E42, -E33 : INC, HC
R-A47, -A42, -A33 : ABS
(HC
R-A47 can also be used with the INC system)
Motor capacity symbol
103
153
203
Connected amplifier type (MDS-B-)
No. Abbrev.
Parameter
name
SVJ2-10 SVJ2-10
(Caution) SVJ2-20
SV001
PC1
Motor side gear ratio
SV002
PC2
Machine side gear ratio
Set the motor side gear ratio in PC1 and the machine side gear ratio in
PC2.
When using a rotary axis, set the total deceleration (acceleration) ratio.
SV003 PGN1 Position loop gain 1
33
SV004 PGN2 Position loop gain 2
0
SV005 VGN1 Speed loop gain
Refer to 4-2-4 Parameters set according to machine load inertia
SV006 –
–
0
SV007 –
–
0
SV008
VIA
Speed loop lead compensation
Refer to 4-2-4 Parameters set according to machine load inertia
SV009 IQA
Current loop q axis lead
compensation
8192
8192 8192
SV010 IDA
Current loop d axis lead
compensation
8192
8192 8192
SV011
IQG
Current loop q axis gain
384
384
256
SV012
IDG
Current loop d axis gain
384
384
256
SV013
ILMT Current limit value
500
SV014 ILMTsp Current limit value in special control
500
SV015
FFC
Acceleration rate feed forward gain
0
SV016 LMC1 Lost motion compensation 1
0
SV017 SPEC Servo specification selection
Refer to 4-2-1 Servo specification parameters
SV018
PIT
Ball screw pitch
Set the ball screw pitch with an mm unit.
Set 360 for a rotary axis.
SV019 RNG1 Position detector resolution
SV020 RNG2 Speed detector resolution
Set to 100 for the HC
R-A47, -E42, -A42 Series
Set to 25 for the HC
R-E33, -A33 Series
SV021
OLT
Overload time constant
60
SV022
OLL
Overload detection level
150
SV023 OD1
Excessive error detection width
during servo ON
Refer to 4-2-3 Parameters set according to feedrate
SV024 INP In-position
width
50
SV025 MTYP Motor/Detector
type
22E1
22E2
22E3
SV026 OD2
Excessive error detection width
during servo OFF
Refer to 4-2-3 Parameters set according to feedrate
SV027 SSF1 Servo function selection 1
4000
SV028
~ 035
–
Compensation function for special
functions
0
SV036 PTYP Regenerative resistor type
Refer to 4-2-1 Servo specification parameters
SV037
~ 046
–
Compensation function for special
functions
0
SV047
EC
Inductive voltage compensation gain
100
SV048 EMGrt Vertical axis drop prevention time
0
SV049
PGN1sp
Position loop gain 1 in spindle
synchronous control
15
SV050
~ 064
–
Compensation function for special
functions
0
CAUTION
Pay close attention to the connection amplifier capacity of the HC153R.
Содержание MELDAS MDS-B-SVJ2 Series
Страница 1: ......
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 46: ......
Страница 92: ......
Страница 108: ......
Страница 152: ......
Страница 186: ......
Страница 194: ......
Страница 218: ......
Страница 260: ......
Страница 282: ......
Страница 283: ...12 1 Chapter 12 Inspections 12 1 Inspections 12 2 12 2 Life parts 12 2 ...
Страница 294: ......
Страница 297: ......