18
MAC-333IF-E
(8) Details of remote control (ON/OFF operation with instantaneous contact)
Brown
Red
Orange
ON
1
2
3
4
5
6
7
8
OFF
Function
summary
Using instantaneous contact switches, the room air conditioner can be turned On and OFF.
System
configuration
MAC333IF-E
· The switches can be used on the following condition:
12 VDC, 0.5 to 2.0 mA
3
2
1
Switch 1
Switch 2
a
CN591
SYSTEM CONTROL Interface
Behavior
· Every time it closes instantaneously, the air conditioner turns ON.
(Unless other controllers are operated, regardless of how often it closes instantaneously, the air conditioner continues to be in operating state.)
· Switch 2
· Every time it closes instantaneously, the air conditioner turns OFF.
(Unless other controllers are operated, regardless of how often it closes instantaneously, the air conditioner continues to be in stopped state.)
* The system control interface will process the last command among those sent by Switch 1, Switch 2, the paired remote controller,
and the M-NET system controller.
· Switch 1
Switch setting
· Settings for the input mode and the input change
Set the state-fixed operation using instantaneous contact switches.
SW No.
Dip switch
Operating details
SW502
· SW502-2,4: ON
· SW502-3: OFF
ON
1
2
3
4
5
6
7
8
OFF
SW500
· SW500-6,8: OFF
Specifications
of communication
cable
· Cable type
a: Sheathed cable, size 0.3 mm
2
or more
· Cable length
a: Cable size is 0.3 mm
2
: 50 m or less / Cable size is 0.5 mm
2
: 100 m or less
Note
· The operation with the paired remote controller is always enabled.
· Switch 1 and 2 operate when the input signal is 200 ms or more. They may not detect the signal of less than 200 ms.
· When the interface is connected to the M-NET system, if the system controller prohibits the manual ON/OFF operation, the ON/OFF
operation from the Switch 1 and 2 is prohibited.
· When the group setting is made with the M-NET system or the MA remote controller, connect Switch 1 and 2 to the interface with the
lowest M-NET address or refrigerant address. The wireless remote controller cannot be used together.
Содержание MAC-333IF-E
Страница 1: ...2012 SYSTEM CONTROL INTERFACE Model MAC 333IF E TECHNICAL MANUAL ...
Страница 2: ...B ...
Страница 29: ......
Страница 30: ......