8 - 8
8. OPTION
8.5 Protective Cover for Oil
POINT
POINT
POINT
(1) Precautions on installation
Tighten the mounting screws within the specified torque range.
• Specified torque range (0.3 to 0.5N·m)
Undertightening can cause a drop. Also, undertightening can disable waterproof or oil proof effect.
Overtightening can cause a drop, short circuit or malfunction due to the damage of the GOT or the mounting
fixtures. Also, "distortion" of the GOT or the panel may disable waterproof or oil proof effect.
(2) Precautions for protective cover for oil
• The protective cover for oil is a consumable product.
Check the cover for scratch, damage or dirt at regular intervals, and replace with new one if necessary.
• Do not push the protective cover for oil with pointed tools, including mechanical pencils and screwdrivers.
Doing so causes scratches and damages of the cover.
• Do not clean the protective cover for oil with bleaches, thinners, organic solvents, corrosive chemicals, and
others. Doing so causes changes in shape and color of the cover.
• When the protective cover for oil is attached to the GOT, do not stretch and bend the cover too much. Doing
so may cause a separation between the sheet and rubber.
• Do not place or use the protective cover for oil in direct sunshine.
• When the protective cover for oil gets dusts, wipe the dusts off with a damp cloth.
• Do not do a frequent detaching the protective cover for oil.
It causes deterioration in the oil performance and the medicine performance.
• It is not the one to guarantee all customer's environments.
Moreover, it is not likely to be able to use it in the environment to which oil splashes for a long time and the
environment with which Oilmist is filled.
3.
The oil cover was hung and the edge of the oil cover is
sequentially obtained and obtain the oil cover to cover
rubber packing parts in the back of GOT of the front
panel.
(From A side to D side, in the direction of the arrow)
4.
Please confirm all surroundings. Check whether the
rubber packing is fitted correctly into the groove on the
under side of the GOT front panel, and then whether
the protective cover for oil securely covers the rubber
packing part to prevent invasion of liquids into the
board.
5.
Mount the GOT onto the control panel. When the
control panel is dirty, clean the control panel. The
panel cutting dimensions and mounting screw
tightening torque with the protective cover for oil are
the same as those without the cover.
The corner on the left is hung and the oil cover is hung
from A side to D side on the starting point sequentially.
D
C
B
A
Make sure that corners of protective
cover for oil match those of GOT front.
Panel cut
dimensions
Mounting metal fixture
Control panel
Protectivecover
for oil
Содержание Got 1000
Страница 1: ......
Страница 2: ......
Страница 14: ...A 12 ...
Страница 26: ...1 4 1 OVERVIEW 1 1 Features ...
Страница 34: ...2 8 2 SYSTEM CONFIGURATION 2 2 System Equipment ...
Страница 38: ...3 4 3 SPECIFICATIONS 3 3 Power Supply Specifications ...
Страница 42: ...4 4 4 PARTS NAME 4 3 Rear Face ...
Страница 54: ...6 6 6 INSTALLATION 6 5 Installation Procedure ...
Страница 104: ...10 18 10 COMMUNICATION INTERFACE SETTING COMMUNICATION SETTING 10 3 Ethernet Setting ...
Страница 134: ...12 4 12 CLOCK SETTINGS AND BATTERY STATUS DISPLAY TIME SETTING AND DISPLAY 12 1 Time Setting and Display ...
Страница 226: ...13 92 13 FILE DISPLAY AND COPY PROGRAM DATA CONTROL 13 2 Various Data Control ...
Страница 250: ...15 2 15 CLEANING DISPLAY SECTION CLEAN ...
Страница 264: ...16 14 16 INSTALLATION OF COREOS BOOTOS AND STANDARD MONITOR OS 16 5 CoreOS ...
Страница 272: ...17 8 17 MAINTENANCE AND INSPECTION 17 5 Backlight Shutoff Detection ...
Страница 298: ...App 6 APPENDICES Appendix 1 External Dimensions ...
Страница 302: ...App 10 APPENDICES Appendix 3 Transportation Precautions ...
Страница 306: ...REVISIONS 2 ...
Страница 309: ......
Страница 310: ......