8 PROFIBUS Configuration Tool
8.3 "PROFIBUS Network" window
87
8
Slave Settings
Set the slave parameters.
[PROFIBUS Network]
Right-click the DP-Slave
[Slave Settings]
Item
Description
Setting range
Model
Displays the model name of the DP-Slave.
Vendor
Displays the manufacturer of the DP-Slave.
Revision
Displays the version of the GSD file or that of the device.
Name
Sets the name of the DP-Slave.
Up to 16 alphanumeric
characters
FDL Address
Sets the FDL address.
0 to 125
min T_sdr
Sets the minimum response time for sending the response frame from the DP-Slave to the master
module.
Do not change this setting.
1 to 255
Group identification
number
Sets the group number (Grp 1 to Grp 8) of the DP-Slave.
Multiple group numbers can be set.
The group number set in this item is used for the global control function service (SYNC, UNSYNC,
FREEZE, and UNFREEZE).
• Not checked: Not belong to the relevant group number.
• Checked: Belongs to the relevant group number.
• Not checked
• Checked
(Default: Not checked)
Slave is active
Unchecks this box to set the DP-Slave as a reserved station.
• Not checked: Sets the DP-Slave as a reserved station.
• Checked: Sets the DP-Slave as the station that performs data exchange.
• Not checked
• Checked
(Default: Checked)
Sync (Output)
Checks this box to check whether the DP-Slave supports the SYNC function during initialization
communications.
When the DP-Slave does not support the SYNC function, the diagnostic information is stored in
'Diagnostic information area' (Un\G23072 to Un\G23199) of the master module.
This item can be set when the DP-Slave supports this function.
• Not checked: Not perform the function check.
• Checked: Perform the function check.
• Not checked
• Checked
(Default: Not checked)
Freeze (Input)
Checks this box to check whether the DP-Slave supports the FREEZE function during initialization
communications.
When the DP-Slave does not support the FREEZE function, the diagnostic information is stored in
'Diagnostic information area' (Un\G23072 to Un\G23199) of the master module.
This item can be set when the DP-Slave supports this function.
• Not checked: Not perform the function check.
• Checked: Perform the function check.
• Not checked
• Checked
(Default: Not checked)
Ignore AutoClear
Checks this box when a clear request is not sent by a communication error detect of the DP-Slave
since the setting in the "Error action flag" of the master parameter is to send it to all DP-Slaves in a
communication error occurrence. (
• Not checked: Enables the "Error action flag" setting.
• Checked: Disables the "Error action flag" setting.
• Not checked
• Checked
(Default: Not checked)
Содержание FX5-DP-M
Страница 1: ...MELSEC iQ F FX5 User s Manual PROFIBUS ...
Страница 2: ......
Страница 9: ...7 MEMO ...
Страница 12: ...10 INDEX 168 REVISIONS 170 WARRANTY 171 TRADEMARKS 172 ...
Страница 13: ...11 CONTENTS ...
Страница 19: ...1 DESCRIPTION 17 1 MEMO ...
Страница 100: ...98 9 PROGRAMMING 9 2 DP Master settings DP Slave FDL address 2 ...
Страница 101: ...9 PROGRAMMING 9 2 DP Master settings 99 9 DP Slave FDL address 3 ...
Страница 108: ...106 9 PROGRAMMING 9 8 Program Example of the Global Control Function ...
Страница 109: ...9 PROGRAMMING 9 8 Program Example of the Global Control Function 107 9 ...
Страница 110: ...108 9 PROGRAMMING 9 8 Program Example of the Global Control Function ...
Страница 112: ...110 9 PROGRAMMING 9 9 Program Example of Acyclic Communication Acyclic Communication ...
Страница 114: ...112 9 PROGRAMMING 9 10 Program Example of the Alarm Acquisition Function ...
Страница 169: ...APPX Appendix 4 Processing Time 167 A MEMO ...
Страница 175: ......