23
RESTRICTIONS ON THE FUNCTIONS
REMARKS
Whether the I/O terminal function in the SSCNET communication operation mode is valid or invalid is indicated by O or X.
Input Signal
Signal name
Va-
lidity
RL
Low-speed operation command
(Pr. 59 = 0)
X
Remote setting (setting clear)
(Pr. 59 = other than 0)
X
RM
Mid-speed operation command
(Pr. 59 = 0)
X
Remote setting (deceleration)
(Pr. 59 = other than 0)
X
RH
High-speed operation command
(Pr. 59 = 0)
X
Remote setting (acceleration)
(Pr. 59 = other than 0)
X
RT
Second function selection/
second motor switchover
X
JOG
Jog operation selection
X
REX
15 speed selection
(Combination with three speeds RL,
RM, RH)
X
X9
Third function selection
X
X10
FR-HC, FR-CV connection
(Inverter operation enable
signal)
O
X11
FR-HC connection
(instantaneous power failure
detection)
X
X12
PU operation external interlock
signal
X
X14
PID control enable terminal
X
BRI Brake sequence opening signal
X
X16
PU operation/external operation
switchover
X
X20
S-pattern acceleration/
deceleration C switchover
terminal
X
X22
Orientation command
X
LX
Pre-excitation/servo on
X
MRS
Output stop
O
STOP
Start self-hold selection
X
MC
Control mode switchover
X
TL
Torque restriction selection
X
X42
Torque bias selection 1
X
X43
Torque bias selection 2
X
X44
P control selection
(P/PI control switchover)
X
X45
Servo on (position control)
X
STR
Reverse rotation command
X
STF
Forward rotation command
X
OH
External thermal relay
O
-
No function
O
RES
Reset
O
1
Speed setting auxiliary input
X
2
Speed setting input
X
Input Signal
Signal name
Va-
lidity
Output Signal
Signal name
Va-
lidity
RUN
Inverter running
O
SU
Up to speed
X
IPF
Instantaneous power
failure or undervoltage
O
OL
Overload alarm
O
FU,
FB
Output speed detection
O
FU2,
FB2
Second output speed
detection
O
FU3,
FB3
Third output speed
detection
O
RBP
Regenerative brake
prealarm
O
THP
Electronic thermal
overload protection
prealarm
O
PU
PU operation mode
X
RY
Inverter operation ready
O
Y12 Output current detection
O
Y13
Zero current detection
O
FDN
PID lower limit
X
FUP
PID upper limit
X
RL
PID forward/reverse
rotation output
X
BOF
Brake opening request
X
FAN
Fan fault output
O
FIN
Heatsink overheat
prealarm
O
ORA
Orientation in-position
X
Y30
Output during forward
rotation
O
Y31
Output during reverse
rotation
O
Y32
Regeneration status
output
O
RY2
Operation ready 2
O
LS
Low speed output
O
TU
Torque detection
O
Y36
In-position
O
MT Maintenance timer output
O
Y40
Trace status
O
RUN
2
Inverter running 2
O
REM
Remote output*
O
ER
Minor fault output 2
X
LF
Minor fault output
O
ABC
Alarm output
O
-
No function
O
Output Signal
Signal name
Va-
lidity
* The function using the PU
connector is valid.
Содержание FR-V5NS
Страница 1: ......
Страница 2: ......
Страница 3: ......
Страница 4: ......
Страница 5: ......
Страница 6: ......
Страница 7: ......
Страница 8: ......
Страница 9: ......
Страница 10: ......
Страница 11: ......
Страница 12: ......
Страница 13: ......
Страница 14: ......
Страница 15: ......
Страница 16: ......
Страница 17: ......
Страница 18: ......
Страница 19: ......
Страница 20: ......
Страница 21: ......
Страница 22: ......
Страница 23: ......
Страница 24: ......
Страница 25: ......
Страница 26: ......
Страница 27: ......
Страница 28: ......
Страница 29: ......
Страница 30: ......
Страница 31: ......
Страница 32: ......
Страница 33: ......