4.1 Parameter List
PARAMETERS
60
4 PARAMETERS
4.1 Parameter List
4.1.1 Parameter list
Func-
tion
Para-
meter
Number
Name
Setting
Range
Minimum
Setting
Increments
Factory
Setting
Refer
To:
Custo-
mer
Setting
0
Torque boost (Note 1)
0 to 30%
0.1%
6%/4%
(Note 8)
69
1
Maximum frequency
0 to 120Hz
0.01Hz
(Note 3)
120Hz
70
2
Minimum frequency
0 to 120Hz
0.01Hz
(Note 3)
0Hz
70
3
Base frequency (Note 1)
0 to 400Hz
0.01Hz
(Note 3)
50Hz
71
4
Multi-speed setting
(high speed)
0 to 400Hz
0.01Hz
(Note 3)
50Hz
72
5
Multi-speed setting
(middle speed)
0 to 400Hz
0.01Hz
(Note 3)
30Hz
72
6
Multi-speed setting
(low speed)
0 to 400Hz
0.01Hz
(Note 3)
10Hz
72
7
Acceleration time
0 to 3600 s/
0 to 360 s
0.1 s/0.01 s
5 s/10s
(Note 4)
73
8
Deceleration time
0 to 3600 s/
0 to 360 s
0.1 s/0.01 s
5 s/10s
(Note 4)
73
Basic f
unct
ions
9
Electronic thermal O/L relay
0 to 500A
0.01A
Rated
output
current
(Note 5)
75
10
DC injection brake operation
frequency
0 to 120Hz
0.01Hz
(Note 3)
3Hz
76
11
DC injection brake operation
time
0 to 10 s
0.1 s
0.5 s
76
12
DC injection brake voltage
0 to 30%
0.1%
6%
76
13
Starting frequency
0 to 60Hz
0.01Hz
0.5Hz
77
14
Load pattern selection
(Note 1)
0 to 3
1
0
78
15
Jog frequency
0 to 400Hz
0.01Hz
(Note 3)
5Hz
79
16
Jog acceleration/
deceleration time
0 to 3600 s/
0 to 360 s
0.1 s/ 0.01 s
0.5 s
79
18
High-speed maximum
frequency
120 to
400Hz
0.1Hz
(Note 3)
120Hz
70
19
Base frequency voltage
(Note 1)
0 to 1000V,
8888,9999
0.1V
8888
71
20
Acceleration/deceleration
reference frequency
1 to 400Hz
0.01Hz
(Note 3)
50Hz
73
21
Acceleration/deceleration
time increments
0, 1
1
0
73
22
Stall prevention operation
level
0 to 200%
0.1%
150%
80
23
Stall prevention operation
level compensation factor at
double speed
(Note 6)
0 to 200%,
9999
0.1%
9999
80
24
Multi-speed setting (speed 4)
0 to 400Hz,
9999
0.01Hz
(Note 3)
9999
72
25
Multi-speed setting (speed 5)
0 to 400Hz,
9999
0.01Hz
(Note 3)
9999
72
St
andard operat
ion f
unct
ions
26
Multi-speed setting (speed 6)
0 to 400Hz,
9999
0.01Hz
(Note 3)
9999
72
Parameter L
ist