PARAMETERS
129
<Setting items and set data>
After completion of parameter settings, set the instruction codes and data then start
communication from the computer to allow various types of operation control and
monitoring.
No.
Item
Instruction
Code
Description
Number of
Data Digits
(Data code
FF=1)
PU mode
Communication
H0001: External operation
H0002: Communication
operation
Read
H7B
NET mode
Communication
H0000: Computer link operation
H0001: External operation
H0002: PU operation
PU mode
Communication
H0001: External operation
H0002: Communication
operation
1
Operation
mode
Write
HFB
NET mode
Communication
H0000: Computer link operation
H0001: External operation
4 digits
Output
frequency
[speed]
H6F
H0000 to HFFFF:Output frequency
(hexadecimal) in 0.01Hz
increments
[Speed (hexadecimal) in
r/min increments if Pr. 37 =
1 to 9998]
4 digits
(6 digits)
Output current
H70
H0000 to HFFFF: Output current (hexadecimal)
in 0.01A increments
4 digits
Output voltage
H71
H0000 to HFFFF: Output voltage
(hexadecimal) in 0.1V
increments
4 digits
H0000 to HFFFF: Two most recent alarm
definitions
Alarm definition display
example (instruction code
H74)
b15
b8b7
b0
0 0 1 1 0 0
0
0
0 0 0 0 0
0
1
1
Previous alarm
(H30)
Most recent alarm
(HA0)
Alarm data
Datza
Description
Data
Description
H00
No alarm
H70
BE
H10
OC1
H80
GF
H11
OC2
H81
LF
H12
OC3
H90
OHT
H20
OV1
HA0
OPT
H21
OV2
HB0
PE
H22
OV3
HB1
PUE
H30
THT
HB2
RET
H31
THM
HF3
E. 3
H40
FIN
HF6
E. 6
H60
OLT
HF7
E. 7
2
M
onit
o
ring
Alarm
definition
H74 to
H77
4 digits
4