69
Dancer control with winding diameter
compensation for printers
712
Initial winding diameter calculation
dead zone 2
9999
0%
Setting to reduce large dancer movement when shifting to normal
operation after initial winding diameter calculation has completed.
720
Maximum winding diameter 1
2mm
1000mm Initial diameters (maximum value at unwinding shaft, minimum
value at winding shaft) should be input accurately.
721
Minimum winding diameter 1
1mm
100mm
756
First acceleration time for main speed
15s
0s
Less time than acceleration/deceleration of main speed setting
(terminal 2-5) is set.
(In this case, cushion time is already included by the high-order
system.)
757
First deceleration time for main speed
15s
0s
763
Line speed input selection
0
0
No line speed input (line speed is calculated from main speed.)
771
r-r' limit value (diameter)
1mm
0.2mm
Longer value than the increment in winding diameter calculation
at
Pr. 707
Sampling time for winding diameter calculation
is set.
773
Gear ratio numerator (driver side)
1
1
Gear ratio of unwinding shaft is set.
Should be set accurately.
774
Gear ratio denominator (follower side)
1
3
777
Speed control proportional gain 1
9999
60%
Response level is improved by adjusting the speed control
proportional gain according to the winding diameter. Speed
control proportional gain is adjusted with maximum diameter
(Pr.
780)
and
minimum diameter
(Pr. 777)
.
Pr. 778
=
/5 +
Pr. 777
,
Pr. 779
= 8
/15 +
Pr. 777
(
=
Pr. 780
-
Pr. 777
)
778
Speed control proportional gain 2
9999
80%
779
Speed control proportional gain 3
9999
120%
780
Speed control proportional gain 4
9999
200%
781
Winding diameter storage selection
0
1
Input of diameter clear signal X55 is necessary to assign to a
terminal when winding diameter storage is enabled.
Winding diameter (EEPROM write) is stored when power is shut
off or X83 is OFF.
It is not stored to EEPROM when RES signal is ON. Should not
input RES unless inverter alarm or fault occurs.
When RES input is necessary for an inverter alarm or in such
case, turn X83 signal OFF before RES input, then input X83
again so that stored winding diameter can be used.
783
Operation time with stored winding
diameter
0
0.01s
Setting is always necessary to activate winding diameter storage.
(If not set, stored data is not updated.)
785
Terminal 4 function setting
9999
2
2: Analog input signal for taper setting
787
Taper ratio setting
100
9999
9999: Terminal 4 input
788
Winding diameter at taper start
9999
800mm
789
Dancer tension setting
100%
100%
790
Initial winding diameter calculation
start point
400%
500.0%
791
Initial winding diameter calculation
dead zone
1.0%
10%
792
Accumulated amount
160mm
270mm
Measured value is 300mm. As initial winding diameter calculation
dead zone
(Pr. 791)
= 10%, 300mm
0.9 = 270mm.
795
Integral term limit at a start
2.5%
1.5%
Setting to adjust the winding speed at initial winding diameter
when tension is applied.
796
PID term limit at a start
2.5%
1.5%
797
Rotation speed at winding diameter
calculated value activation
3Hz
1Hz
800
Control method selection
20
0
0: Vector control (speed control)
821
Speed control integral time 1
0.333s
0s
When dancer control is activated, integral time is set invalid so
that the inverter operates as a proportional amplifier.
862
Notch filter time constant
0
10
Setting to reduce whining sound at a motor stop.
863
Notch filter depth
0
2
868
Terminal 1 function assignment
0
9999
9999: No function (so that voltage input by dancer control is not
compensated when X83 signal is OFF.)
902
Terminal 2 frequency setting bias
0Hz/0%
0Hz/3% Calibration of offset for speed commands.
903
Terminal 2 frequency setting gain
60Hz/
10V
79.58Hz
/100%
V
max
= 200m/min, 10V input, D
min
= 100mm, gear ratio = 1/3
Set according to the rotation speed at V
max,
D
min
and the speed
command at the time (maximum voltage command for terminal 2 to 5.)
= V
max
/(
D
min
gear ratio) = 200
10
3
/(
100
1/3)/30
79.58Hz
904
Terminal 4 frequency setting bias
20%
0%
Calibration of taper ratio setting
905
Terminal 4 frequency setting gain
100%
40%
Parameter
Name
Initial
Value
Setting
Description