8
PARAMETER LIST
455
Second motor excitation current
0 to 500A, 9999/
0 to 3600A, 9999
0.01/0.1A
9999
—
456
Rated second motor voltage
0 to 1000V
0.1V
200/400V
—
457
Rated second motor frequency
10 to 120Hz
0.01Hz
60Hz
—
458
Second motor constant (R1)
0 to 50
, 9999/
0 to 400m
, 9999
0.001
/0.01m
9999
—
459
Second motor constant (R2)
0 to 50
, 9999/
0 to 400m
, 9999
0.001
/
0.01m
9999
—
460
Second motor constant (L1)
0 to 50
(0 to 1000mH),
9999/0 to 3600m
(0 to
400mH), 9999
0.001
(0.1mH)/
0.01m
(0.01mH)
9999
—
461
Second motor constant (L2)
0 to 50
(0 to 1000mH),
9999/0 to 3600m
(0 to
400mH), 9999
0.001
(0.1mH)/
0.01m
(0.01mH)
9999
—
462
Second motor constant (X)
0 to 500
(0 to 100%),
9999/0 to 100
(0 to 100%),
9999
0.01
(0.1%)/
0.01
(0.01%)
9999
—
463
Second motor auto tuning setting/status 0, 1, 101
1
0
—
464
Second PID proportional band
0.1 to 1000%, 9999
0.1%
9999
465
Second PID integral time
0.1 to 3600s, 9999
0.1s
9999
466
Second PID differential time
0.01 to 10s, 9999
0.01s
9999
467
Second PID proportional band for
under-set point value
0.1 to 1000%, 9999
0.1%
9999
468
Second PID integral time for under-set
point value
0.1 to 3600s, 9999
0.1s
9999
469
Second PID differential time for under-
set point value
0.01 to 10s, 9999
0.01s
9999
470
Third PID proportional band
0.1 to 1000%, 9999
0.1%
9999
471
Third PID integral time
0.1 to 3600s, 9999
0.1s
9999
472
Third PID differential time
0.01 to 10s, 9999
0.01s
9999
473
Third PID proportional band for under-
set point value
0.1 to 1000%, 9999
0.1%
9999
474
Third PID integral time for under-set
point value
0.1 to 3600s, 9999
0.1s
9999
475
Third PID differential time for under-set
point value
0.01 to 10s, 9999
0.01s
9999
476
Fourth PID proportional band
0.1 to 1000%, 9999
0.1%
9999
477
Fourth PID integral time
0.1 to 3600s, 9999
0.1s
9999
478
Fourth PID differential time
0.01 to 10s, 9999
0.01s
9999
479
Fourth PID proportional band for under-
set point value
0.1 to 1000%, 9999
0.1%
9999
480
Fourth PID integral time for under-set
point value
0.1 to 3600s, 9999
0.1s
9999
481
Fourth PID differential time for under-
set point value
0.01 to 10s, 9999
0.01s
9999
495
Remote output selection
0, 1, 10, 11
1
0
—
496
Remote output data 1
0 to 4095
1
0
—
497
Remote output data 2
0 to 4095
1
0
—
503
Maintenance timer
0(1 to 9998)
1
0
—
504
Maintenance timer alarm output set
time
0 to 9998, 9999
1
9999
—
505
Speed setting reference
1 to 120Hz
0.01Hz
60Hz
—
516
S-pattern time at a start of acceleration
0.1 to 2.5s
0.1s
0.1s
—
517
S-pattern time at a completion of
acceleration
0.1 to 2.5s
0.1s
0.1s
—
518
S-pattern time at a start of deceleration
0.1 to 2.5s
0.1s
0.1s
—
519
S-pattern time at a completion of
deceleration
0.1 to 2.5s
0.1s
0.1s
—
539
Modbus-RTU communication check
time interval
0 to 999.8s, 9999
0.1s
9999
—
Parameter
Name
Setting Range
Minimum
Setting
Increments
Initial
Value
Refer
to
Page
Customer
Setting