12
PARAMETER LIST
850
Brake operation selection
0, 1
1
0
—
853
Speed deviation time
0 to 100s
0.1s
1s
—
854
Excitation ratio
0 to 100%
1%
100%
—
858
Terminal 4 function assignment
0, 1, 4, 9999
1
0
—
859
Torque current
0 to 500A, 9999/
0 to 3600A, 9999
0.01/0.1A
9999
—
860
Second motor torque current
0 to 500A, 9999/
0 to 3600A, 9999
0.01/0.1A
9999
—
862
Notch filter time constant
0 to 60
1
0
—
863
Notch filter depth
0 to 3
1
0
—
864
Torque detection
0 to 400%
0.1%
150%
—
865
Low speed detection
0 to 400Hz
0.01Hz
1.5Hz
—
866
Torque monitoring reference
0 to 400%
0.1%
150%
—
867
AM output filter
0 to 5s
0.01s
0.01s
—
868
Terminal 1 function assignment
0 to 6, 9999
1
0
—
872
Input phase loss protection selection
0, 1
1
0
—
873
Speed limit
0 to 120Hz
0.01Hz
20Hz
—
874
OLT level setting
0 to 200%
0.1%
150%
—
875
Fault definition
0, 1
1
0
—
877
Speed feed forward control/model
adaptive speed control selection
0, 1, 2
1
0
—
878
Speed feed forward filter
0 to 1s
0.01s
0s
—
879
Speed feed forward torque limit
0 to 400%
0.1%
150%
—
880
Load inertia ratio
0 to 200times
0.1times
7times
—
881
Speed feed forward gain
0 to 1000%
1%
0%
—
882
Regeneration avoidance operation
selection
0 to 3
1
0
883
Regeneration avoidance operation
level
300 to 800V
0.1V
380/760V
—
884
Regeneration avoidance at
deceleration detection sensitivity
0 to 5
1
0
—
885
Regeneration avoidance compensation
frequency limit value
0 to 10Hz, 9999
0.01Hz
6Hz
—
886
Regeneration avoidance voltage gain
0 to 200%
0.1%
100%
—
888
Free parameter 1
0 to 9999
1
9999
—
889
Free parameter 2
0 to 9999
1
9999
—
C0
(900)
FM terminal calibration
—
—
—
—
C1
(901)
AM terminal calibration
—
—
—
—
C2
(902)
Terminal 2 frequency setting bias
frequency
0 to 400Hz
0.01Hz
0Hz
—
C3
(902)
Terminal 2 frequency setting bias
0 to 300%
0.1%
0%
—
125
(903)
Terminal 2 frequency setting gain
frequency
0 to 400Hz
0.01Hz
60Hz
—
C4
(903)
Terminal 2 frequency setting gain
0 to 300%
0.1%
100%
—
C5
(904)
Terminal 4 frequency setting bias
frequency
0 to 400Hz
0.01Hz
0Hz
—
C6
(904)
Terminal 4 frequency setting bias
0 to 300%
0.1%
20%
—
126
(905)
Terminal 4 frequency setting gain
frequency
0 to 400Hz
0.01Hz
60Hz
—
C7
(905)
Terminal 4 frequency setting gain
0 to 300%
0.1%
100%
—
C12
(917)
Terminal 1 bias frequency (speed)
0 to 400Hz
0.01Hz
0Hz
—
Parameter
Name
Setting Range
Minimum
Setting
Increments
Initial
Value
Refer
to
Page
Customer
Setting