![Mitsubishi Electric EZMOTION MR-E Super MR-E-10A-QW003 Скачать руководство пользователя страница 70](http://html.mh-extra.com/html/mitsubishi-electric/ezmotion-mr-e-super-mr-e-10a-qw003/ezmotion-mr-e-super-mr-e-10a-qw003_instruction-manual_238867070.webp)
3 - 39
3. SIGNALS AND WIRING
(b) Connector and signal allotment
When the cable length exceeds 10m, fabricate an extension cable as shown below. In this case, the
motor power supply cable should be within 2m long.
Refer to section 13.1.2 for the wire used for the extension cable.
50m or less
MR-PWS1CBL2M-A1-L
MR-PWS1CBL2M-A2-L
MR-PWS1CBL2M-A1-H
MR-PWS1CBL2M-A2-H
MR-PWS2CBL03M-A1-L
MR-PWS2CBL03M-A2-L
CNP2
AWG 19 (red)
AWG 19 (white)
AWG 19 (black)
AWG19
(green/yellow)
U
V
W
U
V
W
Servo motor
Servo amplifier
M
Extension cable
2m or less
(Note 1)
b) Relay connector for
motor power supply cable
(Note 1)
a) Relay connector
for extension cable
50m or less
24VDC power
supply for
electromagnetic
brake
(Note 4)
Electromagnetic
brake interlock
(MBR)
AWG20
AWG20
MR-BKS1CBL2M-A1-L
MR-BKS1CBL2M-A2-L
MR-BKS1CBL2M-A1-H
MR-BKS1CBL2M-A2-H
MR-BKS2CBL03M-A1-L
MR-BKS2CBL03M-A2-L
(Note 2)
B1
B2
Trouble
(ALM)
2m or less
Emergency stop
(EMG)
Extension cable
(To be fabricated)
(Note 1)
c) Relay connector for
extension cable
(Note 1)
d) Relay connector for
motor brake cable
(Note 3)
Note 1. Use of the following connectors is recommended when ingress protection (IP65) is necessary.
Relay Connector
Description
Protective
Structure
a) Relay connector for
extension cable
Connector: RM15WTPZ-4P(71)
Cord clamp: RM15WTP-CP(5)(71)
(Hirose Electric)
Numeral changes depending on the cable OD.
IP65
b) Relay connector for
motor power supply
cable
Connector: RM15WTJA-4S(71)
Cord clamp: RM15WTP-CP(8)(71)
(Hirose Electric)
Numeral changes depending on the cable OD.
IP65
c) Relay connector for
extension cable
CM10-CR2P-
(DDK)
Wire size: S, M, L
IP65
d) Relay connector for
motor brake cable
CM10-SP2S-
(DDK)
Wire size: S, M, L
IP65
2. Connect a surge absorber as close to the servo motor as possible.
3. There is no polarity in electromagnetic brake terminals (B1 and B2).
4. When using a servo motor with electromagnetic brake, assign the electromagnetic brake interlock (MBR) to
external output signal in the parameters No.PA04, PD13 to PD16 and PD18.
www.DataSheet4U.com
Содержание EZMOTION MR-E Super MR-E-10A-QW003
Страница 17: ...6 MEMO www DataSheet4U com ...
Страница 31: ...2 4 2 INSTALLATION MEMO www DataSheet4U com ...
Страница 85: ...4 6 4 OPERATION MEMO www DataSheet4U com ...
Страница 115: ...5 30 5 PARAMETERS MEMO www DataSheet4U com ...
Страница 149: ...8 10 8 SPECIAL ADJUSTMENT FUNCTIONS MEMO www DataSheet4U com ...
Страница 163: ...10 12 10 TROUBLESHOOTING MEMO www DataSheet4U com ...