15. MR-E- AG-QW003 SERVO AMPLIFIER COMPATIBLE WITH ANALOG INPUT
Class No. Symbol
Name and function
Initial
value
Unit
Setting
range
Control
mode
76
TL2
Internal torque limit 2
Set this parameter to limit servo motor torque on the assumption that the
maximum torque is 100[ ].
When 0 is set, torque is not produced.
When torque is output in analog monitor output, this set value is the
maximum output voltage ( 8V).
100
0
to
100
S T
77
100
78
10000
79
10
80
10
81
100
82
100
83
100
E
xpans
ion param
et
ers
2
84
For manufacturer setting
Do not change this value by any means.
0000