(3) Internal speed setting in speed control mode
(a) Speed command and speed
The servo motor is run at the speed set in parameter No.8 (internal speed command 1) the forward
rotation start (ST1) and reverse rotation start (ST2) are as in section 3.4.2 (1) (a).
Generally, make connection as shown below.
SP2
VIN
SD
Servo amplifier
(b) Speed selection 2 (SP2) and speed command value
Use speed selection 2 (SP2) to select between the speed set by the internal speed command 1 and the
speed set by the Internal speed command 2 as indicated in the following table.
(Note) External input signals
SP1
Speed command value
0
Internal speed command 1 (parameter No.8)
1
Internal speed command 2 (parameter No.9)
Note. 0: SP1-VIN off (open)
1: SP1-VIN on (short)
The speed may also be changed during rotation. In this case, it is increased or decreased according to
the value set in parameter No.11 or 12.
When the internal speed command 1 is used to command the speed, the speed does not vary with the
ambient temperature.
(c) Speed reached (SA)
As in section 3.4.2 (2).
www.DataSheet4U.com
Содержание EZMOTION MR-E Super MR-E-10A-QW003
Страница 17: ...6 MEMO www DataSheet4U com ...
Страница 31: ...2 4 2 INSTALLATION MEMO www DataSheet4U com ...
Страница 85: ...4 6 4 OPERATION MEMO www DataSheet4U com ...
Страница 115: ...5 30 5 PARAMETERS MEMO www DataSheet4U com ...
Страница 149: ...8 10 8 SPECIAL ADJUSTMENT FUNCTIONS MEMO www DataSheet4U com ...
Страница 163: ...10 12 10 TROUBLESHOOTING MEMO www DataSheet4U com ...