5 - 25
5. PARAMETERS
(2) Conveyor setting example
For rotation in increments of 0.01 per pulse
Machine specifications
Table : 360 /rev
Reduction ratio: n 1/18
Servo motor resolution: Pt 10000 [pulses/rev]
Table
Timing belt : 4/64
Servo motor
10000 [pulse/rev]
CDV
CMX
Pt
10000
0.01
1/18 360
20
100
1
5
Hence, set 5 to CMX and 1 to CDV.
5.2.2 Analog monitor
The servo status can be output to two channels in terms of voltage. Using an ammeter enables monitoring the
servo status.
(1) Setting
Change the following digits of parameter No.17.
Analog monitor 1 (MO1) output selection
(Signal output to across MO1-LG)
Analog monitor 2 (MO2) output selection
(Signal output to across MO2-LG)
Parameter No.17
0
0
Parameters No.31 and 32 can be used to set the offset voltages to the analog output voltages. The setting
range is between 999 and 999mV.
Parameter No.
Description
Setting range [mV]
31
Used to set the offset voltage for the analog monitor 1 (MO1) output.
32
Used to set the offset voltage for the analog monitor 2 (MO2) output.
999 to 999
www.DataSheet4U.com
Содержание EZMOTION MR-E Super MR-E-10A-QW003
Страница 17: ...6 MEMO www DataSheet4U com ...
Страница 31: ...2 4 2 INSTALLATION MEMO www DataSheet4U com ...
Страница 85: ...4 6 4 OPERATION MEMO www DataSheet4U com ...
Страница 115: ...5 30 5 PARAMETERS MEMO www DataSheet4U com ...
Страница 149: ...8 10 8 SPECIAL ADJUSTMENT FUNCTIONS MEMO www DataSheet4U com ...
Страница 163: ...10 12 10 TROUBLESHOOTING MEMO www DataSheet4U com ...