![Mitsubishi Electric EZMOTION MR-E Super MR-E-10A-QW003 Скачать руководство пользователя страница 288](http://html.mh-extra.com/html/mitsubishi-electric/ezmotion-mr-e-super-mr-e-10a-qw003/ezmotion-mr-e-super-mr-e-10a-qw003_instruction-manual_238867288.webp)
15 - 29
15. MR-E- AG-QW003 SERVO AMPLIFIER COMPATIBLE WITH ANALOG INPUT
(c) Emergency stop (EMG) OFF
The base circuit is shut off and the dynamic brake is operated to bring the servo motor to a sudden stop.
Alarm AL.E6 (servo emergency stop warning) occurs.
(d) Forward rotation stroke end (LSP), reverse rotation stroke end (LSN) OFF
The servo motor is brought to a sudden stop and servo-locked. The motor may be run in the opposite
direction.
(e) Simultaneous ON or simultaneous OFF of forward rotation start (ST1) and reverse rotation start (ST2)
The servo motor is decelerated to a stop.
POINT
A sudden stop indicates deceleration to a stop at the deceleration time constant
of zero.
www.DataSheet4U.com
Содержание EZMOTION MR-E Super MR-E-10A-QW003
Страница 17: ...6 MEMO www DataSheet4U com ...
Страница 31: ...2 4 2 INSTALLATION MEMO www DataSheet4U com ...
Страница 85: ...4 6 4 OPERATION MEMO www DataSheet4U com ...
Страница 115: ...5 30 5 PARAMETERS MEMO www DataSheet4U com ...
Страница 149: ...8 10 8 SPECIAL ADJUSTMENT FUNCTIONS MEMO www DataSheet4U com ...
Страница 163: ...10 12 10 TROUBLESHOOTING MEMO www DataSheet4U com ...