15 - 16
15. MR-E- AG-QW003 SERVO AMPLIFIER COMPATIBLE WITH ANALOG INPUT
Control
mode
Signal Symbol
Connector
pin No.
Functions/applications
I/O
division
P S
Speed selection 1
SP1
<Speed control mode>
Used to select the command speed for operation.
When using SP1 to SP3, make it usable by making the setting of
parameter No.43 to 48.
DI-1
Speed selection 2
SP2
(Note) Input signals
DI-1
SP3 SP2 SP1
Speed command
Speed selection 3
SP3
0
0
0
Analog speed command (VC)
DI-1
0
0
1
Internal speed command 1 (parameter No.8)
0
1
0
Internal speed command 2 (parameter No.9)
0
1
1
Internal speed command 3 (parameter No.10)
1
0
0
Internal speed command 4 (parameter No.72)
1
0
1
Internal speed command 5 (parameter No.73)
1
1
0
Internal speed command 6 (parameter No.74)
1
1
1
Internal speed command 7 (parameter No.75)
Note. 0: SP1/SP2/SP3-VIN off (open)
1: SP1/SP2/SP3-VIN on (short)
<Speed control mode>
Used to select the command speed for operation.
When using SP1 to SP3, make it usable by making the setting of
parameter No.43 to 48.
(Note) Input signals
SP3
SP2
SP1
Speed limit
0
0
0
Analog speed limit (VLA)
0
0
1
Internal speed limit 1 (parameter No.8)
0
1
0
Internal speed limit 2 (parameter No.9)
0
1
1
Internal speed limit 3 (parameter No.10)
1
0
0
Internal speed limit 4 (parameter No.72)
1
0
1
Internal speed limit 5 (parameter No.73)
1
1
0
Internal speed limit 6 (parameter No.74)
1
1
1
Internal speed limit 7 (parameter No.75)
Note. 0: SP1/SP2/SP3-VIN off (open)
1: SP1/SP2/SP3-VIN on (short)
Control change
LOP
<Position/speed control change mode>
Used to select the control mode in the position/speed control change
mode.
DI-1
(Note)
LOP
Control
mode
0
Position
1
Speed
Note. 0: LOP-VIN off (open)
1: LOP-VIN on (short)
Refer to
func-
tions/
applica-
tions.
Servo-on
SON
CN1-4
Same as MR-E- A-QW003. (Refer to section 3.3.2 (1).)
DI-1
Reset RES
DI-1
Proportion
control
PC
DI-1
Emergency stop
EMG
CN1-8
DI-1
Gain changing
CDP
DI-1
www.DataSheet4U.com
Содержание EZMOTION MR-E Super MR-E-10A-QW003
Страница 17: ...6 MEMO www DataSheet4U com ...
Страница 31: ...2 4 2 INSTALLATION MEMO www DataSheet4U com ...
Страница 85: ...4 6 4 OPERATION MEMO www DataSheet4U com ...
Страница 115: ...5 30 5 PARAMETERS MEMO www DataSheet4U com ...
Страница 149: ...8 10 8 SPECIAL ADJUSTMENT FUNCTIONS MEMO www DataSheet4U com ...
Страница 163: ...10 12 10 TROUBLESHOOTING MEMO www DataSheet4U com ...