66
DISASSEMBLY PROCEDURE
PHOTOS
Photo 8-1
8. How to remove the plate heat exchanger
(1) Pump down the refrigerant circuit and close the stop
valve on the outdoor unit. (Refer to "12. Supplementary
information".)
(2) Remove the front panel. (Refer to Procedure 1.)
(3) Remove the water pump and the pump valve. (Refer to
Procedure 5.)
(4) Remove the expansion vessel. (Refer to Procedure 11.)
<ERSC series>
(5) Remove the saddle band (upper the pump) by removing
the 2 screws. (Photo 8-2)
(6) Remove the pipe (W.C.-W.P.) and the pipe (P.V.-B.H.) by
detaching the quick connections.
•
When reinstalling the quick connections, use new O-rings.
•
Refer to page 77 for how to attach and detach the quick
connection.
Photo 8-2(ERSC series)
Water coil cover
Earth cable
Cable
clamps
Cable strap
Cable strap
Coated clamp
Lead
wire
CNPWM
connector
Water pump
connector (CNP1)
Pump valve
Water pump
Nut (G1")
Nut (G1")
Screws
Screws
Booster heater
Screw
O-ring
O-ring
Expansion vessel
Quick
connection
Plate heat exchanger
(inside)
O-ring
Quick connection
Pipe
(P.V.-B.H.)
Saddle band
(upper the pump)
Pipe
(W.C.-W.P.)
O-ring
Quick connection
Strainer valve
Gasket (G1")
Pipe
(STR-W.C.)
Nut (G1")
OCH571