6
SPECIFICATIONS
3
Model name
EHSD-MEC
EHSD-VM2C
EHSC-MEC
EHSC-VM2C
EHSC-VM2EC
EHSC-VM6C
EHSC-VM6EC
EHSC-YM9C
EHSC-YM9EC
EHSC-TM9C
ERSD-VM2C
ERSC-MEC
ERSC-VM2C
EHPX-VM2C
EHPX-YM9C
Overall unit dimensions
800 × 530 × 360 mm (Height × Width × Depth)
W
eight (empty)
38 kg
44 kg
42 kg
48 kg
43 kg
49 kg
44 kg
49 kg
44 kg
49 kg
45 kg
43 kg
49 kg
37 kg
38 kg
W
eight (full)
44 kg
50 kg
49 kg
55 kg
50 kg
56 kg
51 kg
56 kg
51 kg
56 kg
51 kg
50 kg
56 kg
42 kg
43 kg
Plate heat exchanger (MW
A2)
—
—
—
—
—
Plate heat exchanger (MW
A1)
—
—
—
—
—
—
—
—
—
—
—
—
Cooling mode
NOT
available
Available
NOT
available
Unvented expansion vessel(Primary heat-
ing)
Nominal volume
—
10 L
—
10 L
—
10 L
—
10 L
—
10 L
—
10 L
Charge pressure
—
1 bar
—
1 bar
—
1 bar
—
1 bar
—
1 bar
—
1 bar
Safety device
W
ater
circuit (Pri- mary)
Control thermistor
1 - 80°C
Pressure relief valve
0.3 Mpa (3bar)
Flow sensor
Min flow 5.0 L/min
Booster heater
Manual reset thermostat
—
90°C
—
90°C
—
90°C
Thermal Cut-out (for dry run prevention)
—
121°C
—
121°C
—
121°C
Primary circuit circulating Pump
Grundfos UPM2 15 70 - 130
Connections
W
ater
28mm compression (primary circuit)
G1 (Male)
28mm compression
(primary circuit)
Refrigerant
(R410A)
Liquid
6.35 mm
9.52 mm
6.35 mm
9.52 mm
—
Gas
12.7 mm
15.88 mm
12.7 mm
15.88 mm
—
Target tempera
-
ture range
Flow
temperature
Heating
25 - 60°C
Cooling
—
5 - 25°C
—
Room temperature
Heating
10 - 30 °C
Cooling
—
NOT
available
—
Guaranteed oper
-
ating range
Ambient *1
0 - 35°C (
80 %RH)
Outdoor temperature
Heating
See outdoor unit spec table.
Cooling
—
See outdoor unit spec table
(min. 10°C). *2
—
Electrical data
Control board
Power supply
(Phase, voltage, frequency)
~/N, 230 V
, 50 Hz
Breaker (*when powered
from independent source)
10A
Booster heater
Power supply
(Phase, voltage, frequency)
—
~/N, 230 V
,
50 Hz
—
~/N, 230 V
,
50 Hz
~/N, 230 V
,
50 Hz
~/N, 230 V
,
50 Hz
~/N, 230 V
,
50 Hz
3~, 400 V
,
50 Hz
3~, 400 V
,
50 Hz
3~, 230 V
,
50 Hz
~/N, 230 V
,
50 Hz
—
~/N, 230 V
,
50 Hz
~/N, 230 V
,
50 Hz
3~, 400 V
,
50 Hz
Capacity
—
2kW
—
2kW
2kW
2kW+ 4kW
2kW+ 4kW
3kW+ 6kW
3kW+ 6kW
3kW+ 6kW
2kW
—
2kW
2kW
3kW+ 6kW
Current
—
9 A
—
9 A
9 A
26 A
26 A
13A
13A
23A
9 A
—
9 A
9 A
13A
Breaker
—
16 A
—
16 A
16 A
32 A
32 A
16A
16A
32A
16 A
—
16 A
16 A
16A
Sound level
28 dB(A)
Optional extras
●Wireless Remote Controller
PAR-WT50R-E
●
Tank thermistor (THW5) (30 m)
PAC-TH01
1TKL-E
*1
The environment must be frost-free.
●W
ire
le
ss
R
ec
ei
ve
r
PAR-WR51R-E
●T
he
rm
is
to
r
PAC-TH01
1-E
*2 Low ambient cooling is NOT
allowed.
●R
em
ot
e
S
en
so
r
PAC-SE41TS-E
●High temperature thermistor
PAC-TH01
1HT
-E
●T
ank
ther
m
is
tor
(T
HW
5)
(5
m
)
PAC-TH01
1TK-E
●ecodan Wi-Fi Interface
PAC-WF010-E
<T
able 3-1>
OCH571
Содержание ecodan EHPX-VM2C