69
DISASSEMBLY PROCEDURE
PHOTOS
Photo 8-7(E*SD series)
Plate heat exchanger
(inside)
Water pump
Nut (G1")
Screws
Screws
Screw
Booster heater
Screw
Screws
O-ring
Pipe (P.V.-B.H.)
O-ring
O-ring
Strainer valve
8. How to remove the plate heat exchanger(continued)
Refer to the previous page for step (1) to (5).
(Skip (4).)
<E*SD series>
(6) Remove the pipe (W.C.-W.P) and L joint (upper) together by
detaching the quick connection for the L joint (upper) and the
plate heat exchanger. (Photo 8-7)
•
When reinstalling the quick connection, use new O-ring.
•
Refer to page 77 for how to attach and detach the quick
connection.
(7) Remove the pipe (P.V.-B.H.) by detaching the quick connection.
(Photo 8-7)
•
When reinstalling the quick connection, use new O-ring.
•
Refer to page 77 for how to attach and detach the quick
connection.
(8) Close the strainer valve. (Photo 8-7)
•
When the strainer valve handle is stiff, turn the handle 90 degrees
clockwise mainly by using a spanner. (Photo 8-5)
•
When opening or closing the strainer valve, ensure to do so fully,
not halfway.
(9) Remove the saddle band (upper the strainer) by removing the 2
screws. (Photo 8-7)
(10) Detach the quick connection for the L joint (Lower) and the plate
heat exchnager, and rotate forward the pipe (to W.C.) with the L
joint (lower) by using the quick connection (upper the strainer) as
a fulcrum.
•
When reinstalling the quick connection, use new O-ring.
•
Refer to page 77 for how to attach and detach the quick
connection.
(11) Remove the TH2 thermistor from the thermistor holder. (Photo 8-7)
TH2 thermistor
Pipe (W.C.-W.P.)
Saddle band
(upper the pump)
Quick connection
Saddle band
(upper strainer)
Quick connection
L joint (lower)
Pump valve
Water coil cover
Quick connection
L joint (upper)
Quick connection
(upper strainer)
Pipe (to W.C.)
OCH571