31
<Summary of settings>
This function shows the current installer/user entered settings.
Abbreviation Explanation
Abbreviation Explanation
HWtemp
DHW max temperature
Z2 mode
Operation mode
HWdrop
DHW temperature drop
- HER (Heating room temperature)
HWtime
DHW max operation time
- HE (Heating flow temperature)
NO HW
DHW mode restriction
- HCC (Heating compensation curve)
HWset
DHW operation mode (Normal/Eco)
- COR (—)
- CO (Cooling flow temperature)
Ltemp
Legionella hot water temperature
Hroom 1
Heating target room temperature
Lfreq
Legionella operation Frequency
Hroom 2
Heating target room temperature
Lstart
Legionella mode start time
Hflow 1
Heating target flow temperature
Ltime
Legionella max. operation time
Hflow 2
Heating target flow temperature
Lkeep
Duration of max (Legionella) hot
water temperature
Croom 1
Cooling target room temperature
Croom 2
Cooling target room temperature
Z1 mode
Operation mode
Cflow 1
Cooling target flow temperature
- HER (Heating room temperature)
Cflow 2
Cooling target flow temperature
- HE (Heating flow temperature)
FSflow
Freeze stat function flow temperature
- HCC (Heating compensation curve)
FSout
Freeze stat function ambient temperature
- COR (—)
- CO (Cooling flow temperature)
<Error history>
Error history allows the service engineer to view previous Error codes, the unit
address and the date on which they occurred. Up to 16 Error codes can be stored
in the history the most recent Error event is displayed at the top of the list.
1. From the service menu select Error history
2. Press CONFIRM.
Please see section 10-4. for error code diagnosis and actions.
To delete an Error history item;
1. From Error history screen press F4 button (Rubbish bin icon)
2. Then press F3 button (Yes).
Password input screen
Password verify screen
<Password protection>
Password protection is available to prevent unauthorised access to the service
menu by untrained persons.
1. From the service menu use F1 and F2 buttons to scroll through list until
Password protection is highlighted.
2. Press CONFIRM.
3. When password input screen is displayed use buttons F1 and F2 to move left
and right between the four digits, F3 to lower the selected digit by 1, and F4 to
increase the selected digit by 1.
4. When you have input your password press CONFIRM.
5. The password verify screen is displayed.
6. To verify your new password press button F3.
7. Your password is now set and the completion screen is displayed.
OCH571
Содержание ecodan EHPX-VM2C
Страница 83: ...83 OCH571 ...