DISASSEMBLY PROCEDURE
PHOTOS
71
9. How to remove the strainer
<ERS* / EHS* series>
(1) Remove the front panel. (Refer to Procedure 1.)
(2)
Swing the control box to the front. (Refer to Procedure 4.)
(3) Close the strainer valve (OFF). (Photos 9-1 and 9-4)
•
When the strainer valve handle is stiff, turn the handle
90 degrees clockwise mainly by using a spanner.
•
When opening or closing the strainer valve, ensure to
do so fully, not halfway.
(4) Remove the 2 screws on the strainer valve stay. (Photos
9-1 and 9-4)
(5) Remove the G1" nut using two spanners: one to hold the
strainer and the other to turn the G1" nut.
(Photos 9-1
and 9-4)
•
When reinstalling the G1" nut, use new G1" gasket.
(6) Detach the quick connection. (Photos 9-1 and 9-4)
•
When reinstalling the quick connection, use new O-ring.
•
Refer to page 77 for how to attach and detach the quick
connection.
•
Reuse the removed strainer valve stay and the strainer
valve stay fixing screws.
(Photos 9-2 and 9-5)
<Removal of the strainer cover (debris recovery)>
(4) Remove the cover with two spanners: one to hold the
strainer valve and the other to turn the cover. (Photos 9-1
and 9-4)
•
Be sure to reattach the mesh after washing. (Photo 9-3)
•
When reinstalling the cover , use a new packing.
Photo 9-1(ERS* series)
Photo 9-4(EHS* series)
Photo 9-2(ERS* series)
Photo 9-5(EHSC series)
Strainer mesh
(inside)
Nut
(G1")
Cover
Gasket
(G1")
Photo 9-3
Strainer
valve
O-ring
Strainer mesh
(inside)
Cover
Nut (G1")
Gasket
(G1")
Strainer
valve
Strainer mesh
Packing
Cover
Quick
connection
Strainer
valve stay
Strainer valve stay
Screws
Strainer
valve stay
Screws
O-ring
Quick
connection
Strainer valve stay
Screws
Screw
OCH571