18
PARAMETER LIST
1008 Clock (hour, minute)
0 to 59, 100 to
159, 200 to 259,
300 to 359,
400 to 459,
500 to 559,
600 to 659,
700 to 759,
800 to 859,
900 to 959,
1000 to 1059,
1100 to 1159,
1200 to 1259,
1300 to 1359,
1400 to 1459,
1500 to 1559,
1600 to 1659,
1700 to 1759,
1800 to 1859,
1900 to 1959,
2000 to 2059,
2100 to 2159,
2200 to 2259,
2300 to 2359
0
1015 Integral stop selection
at limited frequency
0 to 2, 10 to 12 0
1016
PTC thermistor
protection detection
time
0 to 60s
0s
1018 Monitor with sign
selection
0, 1, 9999
9999
1020 Trace operation
selection
0 to 4
0
1021 Trace mode selection
0 to 2
0
1022 Sampling cycle
0 to 9
2
1023 Number of analog
channels
1 to 8
4
1024 Sampling auto start
0, 1
0
1025 Trigger mode selection 0 to 4
0
1026 Number of sampling
before trigger
0 to 100%
90%
1027 Analog source selection
(1ch)
1 to 3, 5 to 14,
17 to 20,
22 to 24,
32 to 36,
39 to 42, 46,
52 to 54, 61, 62,
64, 67, 71 to 75,
87 to 98,
201 to 213,
222 to 227,
230 to 232,
235 to 238
201
1028 Analog source selection
(2ch)
202
1029 Analog source selection
(3ch)
203
1030 Analog source selection
(4ch)
204
1031 Analog source selection
(5ch)
205
1032 Analog source selection
(6ch)
206
1033 Analog source selection
(7ch)
207
1034 Analog source selection
(8ch)
208
1035 Analog trigger channel 1 to 8
1
1036 Analog trigger
operation selection
0, 1
0
1037 Analog trigger level
600 to 1400
1000
1038 Digital source selection
(1ch)
1 to 255
1
1039 Digital source selection
(2ch)
2
1040 Digital source selection
(3ch)
3
1041 Digital source selection
(4ch)
4
1042 Digital source selection
(5ch)
5
1043 Digital source selection
(6ch)
6
1044 Digital source selection
(7ch)
7
1045 Digital source selection
(8ch)
8
1046 Digital trigger channel
1 to 8
1
1047 Digital trigger operation
selection
0, 1
0
1048 Display-off waiting time
0 to 60m
0m
1049 USB host reset
0, 1
0
1072
DC brake judgment
time for anti-sway
control operation
0 to 10s
3s
1073 Anti-sway control
operation selection
0, 1
0
1074 Anti-sway control
frequency
0.05 to 3Hz,
9999
1Hz
1075 Anti-sway control depth 0 to 3
0
1076 Anti-sway control width 0 to 3
0
1077 Rope length
0.1 to 50m
1m
1078 Trolley weight
1 to 50000kg
1kg
1079 Load weight
1 to 50000kg
1kg
1103
Deceleration time at
emergency stop
0 to 3600s
5s
1106
Torque monitor filter
0 to 5s, 9999
9999
1107
Running speed monitor
filter
0 to 5s, 9999
9999
Pr.
Name
Setting
range
Initial
value
1108
Excitation current
monitor filter
0 to 5s, 9999
9999
1113
Speed limit method
selection
0 to 2, 10, 9999 9999
1114
Torque command
reverse selection
0, 1
1
1115
Speed control integral
term clear time
0 to 9998ms
0s
1116
Constant output range
speed control P gain
compensation
0 to 100%
0%
1117
Speed control P gain 1
(per-unit system)
0 to 300, 9999
9999
1118
Speed control P gain 2
(per-unit system)
0 to 300, 9999
9999
1119
Model speed control
gain (per-unit system)
0 to 300, 9999
9999
1121
Per-unit speed control
reference frequency
0 to 400 Hz
120Hz
60Hz
1130
Link speed selection
0, 1
0
1134
PID upper limit
manipulated value
0 to 100%
100%
1135
PID lower limit
manipulated value
0 to 100%
100%
1136
Second PID display
bias coefficient
0 to 500, 9999
9999
1137
Second PID display
bias analog value
0 to 300%
20%
1138
Second PID display
gain coefficient
0 to 500, 9999
9999
1139
Second PID display
gain analog value
0 to 300%
100%
1140
Second PID set point/
deviation input
selection
1 to 5
2
1141
Second PID measured
value input selection
1 to 5
3
1142
Second PID unit
selection
0 to 43, 9999
9999
1143
Second PID upper limit 0 to 100%, 9999 9999
1144
Second PID lower limit 0 to 100%, 9999 9999
1145
Second PID deviation
limit
0 to 100%, 9999 9999
1146
Second PID signal
operation selection
0 to 3, 10 to 13 0
1147
Second output
interruption detection
time
0 to 3600s,
9999
1s
1148
Second output
interruption detection
level
0 to 590Hz
0Hz
1149
Second output
interruption cancel level 900 to 1100%
1000%
1150
to
1199
User parameters 1 to
50
0 to 65535
0
1220 Target position/speed
selection
0 to 2
0
1221 Start command edge
detection selection
0, 1
0
1222 First positioning
acceleration time
0.01 to 360s
5s
1223 First positioning
deceleration time
0.01 to 360s
5s
1224 First positioning dwell
time
0 to 20000ms
0ms
1225 First positioning sub-
function
0 to 2, 10 to 12,
100 to 102,
110 to 112
10
1226 Second positioning
acceleration time
0.01 to 360s
5s
1227 Second positioning
deceleration time
0.01 to 360s
5s
1228 Second positioning
dwell time
0 to 20000ms
0ms
1229 Second positioning
sub-function
0 to 2, 10 to 12,
100 to 102,
110 to 112
10
1230 Third positioning
acceleration time
0.01 to 360s
5s
1231 Third positioning
deceleration time
0.01 to 360s
5s
1232 Third positioning dwell
time
0 to 20000ms
0ms
1233 Third positioning sub-
function
0 to 2, 10 to 12,
100 to 102,
110 to 112
10
1234 Fourth positioning
acceleration time
0.01 to 360s
5s
1235 Fourth positioning
deceleration time
0.01 to 360s
5s
1236 Fourth positioning dwell
time
0 to 20000ms
0ms
1237 Fourth positioning sub-
function
0 to 2, 10 to 12,
100 to 102,
110 to 112
10
1238 Fifth positioning
acceleration time
0.01 to 360s
5s
Pr.
Name
Setting
range
Initial
value
1239 Fifth positioning
deceleration time
0.01 to 360s
5s
1240 Fifth positioning dwell
time
0 to 20000ms
0ms
1241 Fifth positioning sub-
function
0 to 2, 10 to 12,
100 to 102,
110 to 112
10
1242 Sixth positioning
acceleration time
0.01 to 360s
5s
1243 Sixth positioning
deceleration time
0.01 to 360s
5s
1244 Sixth positioning dwell
time
0 to 20000ms
0ms
1245 Sixth positioning sub-
function
0 to 2, 10 to 12,
100 to 102,
110 to 112
10
1246 Seventh positioning
acceleration time
0.01 to 360s
5s
1247 Seventh positioning
deceleration time
0.01 to 360s
5s
1248 Seventh positioning
dwell time
0 to 20000ms
0ms
1249 Seventh positioning
sub-function
0 to 2, 10 to 12,
100 to 102,
110 to 112
10
1250 Eighth positioning
acceleration time
0.01 to 360s
5s
1251 Eighth positioning
deceleration time
0.01 to 360s
5s
1252 Eighth positioning dwell
time
0 to 20000ms
0ms
1253 Eighth positioning sub-
function
0 to 2, 10 to 12,
100 to 102,
110 to 112
10
1254 Ninth positioning
acceleration time
0.01 to 360s
5s
1255 Ninth positioning
deceleration time
0.01 to 360s
5s
1256 Ninth positioning dwell
time
0 to 20000ms
0ms
1257 Ninth positioning sub-
function
0 to 2, 10 to 12,
100 to 102,
110 to 112
10
1258 Tenth positioning
acceleration time
0.01 to 360s
5s
1259 Tenth positioning
deceleration time
0.01 to 360s
5s
1260 Tenth positioning dwell
time
0 to 20000ms
0ms
1261 Tenth positioning sub-
function
0 to 2, 10 to 12,
100 to 102,
110 to 112
10
1262 Eleventh positioning
acceleration time
0.01 to 360s
5s
1263 Eleventh positioning
deceleration time
0.01 to 360s
5s
1264 Eleventh positioning
dwell time
0 to 20000ms
0ms
1265 Eleventh positioning
sub-function
0 to 2, 10 to 12,
100 to 102,
110 to 112
10
1266 Twelfth positioning
acceleration time
0.01 to 360s
5s
1267 Twelfth positioning
deceleration time
0.01 to 360s
5s
1268 Twelfth positioning
dwell time
0 to 20000ms
0ms
1269 Twelfth positioning sub-
function
0 to 2, 10 to 12,
100 to 102,
110 to 112
10
1270 Thirteenth positioning
acceleration time
0.01 to 360s
5s
1271 Thirteenth positioning
deceleration time
0.01 to 360s
5s
1272 Thirteenth positioning
dwell time
0 to 20000ms
0ms
1273 Thirteenth positioning
sub-function
0 to 2, 10 to 12,
100 to 102,
110 to 112
10
1274 Fourteenth positioning
acceleration time
0.01 to 360s
5s
1275 Fourteenth positioning
deceleration time
0.01 to 360s
5s
1276 Fourteenth positioning
dwell time
0 to 20000ms
0ms
1277 Fourteenth positioning
sub-function
0 to 2, 10 to 12,
100 to 102,
110 to 112
10
1278 Fifteenth positioning
acceleration time
0.01 to 360s
5s
1279 Fifteenth positioning
deceleration time
0.01 to 360s
5s
1280 Fifteenth positioning
dwell time
0 to 20000ms
0ms
1281 Fifteenth positioning
sub-function
0, 2, 10, 12, 100,
102, 110, 112
10
1282 Home position return
method selection
0 to 6
4
1283 Home position return
speed
0 to 30Hz
2Hz
Pr.
Name
Setting
range
Initial
value
Downloaded from