61
Table 4-1. Ethernet Cable Wiring
4.3.2 SET UP
Setup of the Ethernet Interface should be attempted only after the unit is fully installed
and functioning, in accordance with the Operation and Maintenance Manual. Once
operating, the Ethernet Interface may be configured.
4.3.3 CONFIGURING INTERNET PROTOCOL (IP) OPERATING PARAMETERS
If an IP address cannot be dynamically assigned by the network or the unit is to be
connected directly to a PC then the Internet Protocol (IP) address and associated
parameters must be configured in the unit manually. Normally, an individual or
organization managing the facility’s LAN will assign this address.
For the direct connection to a PC any address can be chosen but the PC must also be
configured correctly. In this configuration, the PC must be configured with a Static IP
address. The procedure for this varies between operating system types and versions.
Consult the operating manual or help files available with the computer to be used to
determine the proper procedure.
Three parameters will be required on the NSU:
IP Address
(NSU example setting 192.168.1.1)
Subnet Mask
(NSU example setting 255.255.255.0)
Gateway
(NSU example setting 0.0.0.0)
The computer must be configured with the same Subnet Mask as the NSU, but a
different IP address, to connect properly. For connecting with the NSU unit address in
the example above, the following settings are recommended for the PC:
IP Address
(Corresponding PC setting 192.168.1.2)
Subnet Mask
(Corresponding PC setting 255.255.255.0)
Gateway
(Corresponding PC setting 0.0.0.0)
The Ethernet address may be configured either via the serial interface (Paragraph 4.3.4)
or via a MITEQ supplied Windows
™
application (Paragraph 4.3.5).
Direct Cable Wiring
End 1
Color
End 2
Signal
1 white/orange 1 Tx+
2 orange
2 Tx-
3 white/green 3 Rx+
4 blue
4 unused
5 white/blue
5 unused
6 green
6 Rx-
7 white/brown 7 unused
8 brown
8 unused
Crossover Cable Wiring
End 1
Color
End 2
1 white/orange 3
2 orange.
6
3 white/green 1
4 blue
4
5 white/blue
5
6 green
2
7 white/brown 7
8 brown
8