SX-200 General Information Guide
214
Revision A
50003510
Site
SX-200 IP Node
Temperature
0º C to 40º C (32º F to 104º F)
Humidity
15 to 95% Relative Humidity, non-condensing
Vibration
0.5 g, 5 to 100 Hz, any orthogonal axis
1.5 g, 100 to 500 Hz, any orthogonal axis
Mechanical
Stress
One 15.3 cm (6 in.) drop, each edge and corner adjacent to the rest face –
unpackaged
One 76.2 cm (30 in.) drop, each edge and corner packaged in
cardboard & foam.
Site Conditions
SX-200 EL/ML System
Operating Temperature
0 to 40º C
32 to 104º F
Relative Humidity (Operating)
(non-condensing)
20 to 80%
20 to 80%
Heat Dissipation (approximate)
500 BTUs / hr
Maximum Altitude
4000 m
13,000 ft.
SX-200 IP Node
Operating Temperature
15º to 35º C
59º to 95º F
Relative Humidity (Operating)
(non-condensing)
40 to 90%
Heat Dissipation - fully loaded*
724 BTUs/hr
Air Flow
150 cubic feet per minute at
maximum output of the fans
Acoustic Emission
Maximum 50 dBA continuous, 75
dB intermittent (<10% duty cycle)
* Conversion factors: 1 watt is equal to 3.412 BTUs per hour, 1 ton of refrigeration is equal to 12,000
BTUs per hour or 3.516 Kilowatts, and 3/4 Kilowatt-hour is equal to 1 ton of refrigeration
Storage Conditions (continued)
Specification
Range
Page 2 of 2
Содержание SX-2000 EL
Страница 1: ...GENERAL INFORMATION GUIDE LIGHTWARE 19 RELEASE 3 1 ...
Страница 14: ...xiv Revision A 50003510 SX 200 General Information Guide ...
Страница 34: ...SX 200 General Information Guide 20 Revision A 50003510 ...
Страница 61: ...Configuration 50003510 Revision A 47 SX 200 ML Configuration Example ...
Страница 114: ...SX 200 General Information Guide 100 Revision A 50003510 ...
Страница 214: ...SX 200 General Information Guide 200 Revision A 50003510 ...
Страница 226: ...SX 200 General Information Guide 212 Revision A 50003510 ...
Страница 257: ...Glossary of Terms 50003510 Revision A 243 NOTES ...
Страница 258: ... Trademark of Corporation Copyright 2003 Corporation All rights reserved Mitel Networks Mitel Networks ...