PRODUCT GENERAL SPECIFICATIONS
TLG TECHNICAL SPECIFICATIONS
Model
TLG
80
TLG
100
TLG
125
TLG
150
TLG
175
TLG
200
Capacity
kcal/h
80.000
100.000
125.000
150.000
175.000
200.000
kW
93
116
145
174
203
232
Width
A
mm
771
771
771
894
894
894
Height
H
mm
791
791
791
914
914
914
Height
H1
mm
968
968
968
1091
1091
1091
Length
L
mm
1349
1429
1529
1529
1629
1629
Foot record
L1
mm
782
882
982
982
1082
1082
Chimney Diameter
E
mm
200
200
200
200
200
200
Chimney Height
H2
mm
550
550
550
665
665
665
Hot Water Flow / Return
F
DN
65
65
65
65
65
65
(PN 16)
lt
118
135
138
240
260
251
Water Volume
kg
425
460
505
610
660
670
Dry Weight
S
inch
1 1/4”
1 1/4”
1 1/4”
1 1/4”
1 1/4”
1 1/4”
Safety Departure / Return
S1
inch
1/2”
1/2”
1/2”
1/2”
1/2”
1/2”
Condensing Expense
C
inch
1/2”
1/2”
1/2”
1/2”
1/2”
1/2”
Back Pressure
mbar
1.2
1.3
1.5
2.2
2.3
2.5
Standard Operating
Pressure
bar
4
4
4
4
4
4
Ekin Endüstriyel MG series gas-fueled heating
boilers are manufactured with three-pass.
Known as scotch type boilers across the globe,
these boilers are preferable because of their high
operating efficiency and long operating life.
High combustion efficiency of 91% and
95% can be achieved thanks to three-pass
combustion system. Thanks to window-type
turbulators (flame breaker) found in third pass
pipes, combustion efficiency increases and fuel
consumption decreases.
Manufactured and projected as per TS 303-1-2-
3 and TS 497 standards, these boilers have CE
document according to B+E module of 92/42/
AT and 2009/142/AT gas fueled hot water boilers
directive.
As per 152.2000 pose included in unit cost
books, preferred by governmental bodies and
institutions, three pass gas-fueled boilers have
thermal efficiency reports as per TS 4040 and TS
4041 standards.