Revision 1.00 beta – April 2019
25
MEMORY delete: To delete memory location go in menu 8 then select needed
memory location with main dial encoder 4 and then long press RIT/XIT
CL
or
encoder 3 button. Channel number starts blinking
7.5. Receiver operation
Make sure the equipment is connected to 13.8V power supply and proper antenna
adjusted for working band. If external headphones are preferred they can be
connected via front panel 3.5mm jack 6 on fig.1. External loud speaker can be
connected via 3.5mm jack 7 fig.2 on real panel. For convenient work the radio body
can be tilted by supplied flipping bail on bottom lid.
Tuning on frequency
Switch on the radio and tune the frequency with main dial knob, UP
REC
and
DOWN
PLY
buttons or direct enter the frequency via numeric pad.
Mode
Choose desired mode of operation – CW, CW-R, USB or LSB. Short press MODE
REV
button toggles between CW and SSB. Long press of the button toggles CW/CW-
R and LSB/USB.
Automatic gain control (AGC)
Set proper AGC delay time by short press of AGC
OFF
button. Usually CW modes
require using fast AGC. Phone modes require slow AGC. Sometimes operator may
need to turn AGC off – by long press of AGC
OFF
button.
PREamplifier and ATTenuator
For bands higher than 10MHz it is recommended to turn on RF preamplifier with
short press of PRE
ATT
button. If the signal is loud and there is too much noises
(QRN or QRM) on the band – switching on of internal 12db attenuator is a good
decision – long press of PRE
ATT.
It is not typical to use same time Attenuator and Preamplifier.
Variable bandwith (Narrow) filter for SSB and CW
If optional variable crystal filter is installed you can swith it on by short press of FLT
button. A small icon
appears on LCD
Rotating encoder 1 selects various filters from b1 to b10. Also chevron symbols just
bellow operating frequency depicts relatively used bandwith.
AF/RG gain set