9. Serivce menu
RGO ONE individual firmware parameters are kept in internal FLASH memory.
These bytes of information are sensitive and the unit might not work properly if they
are changed without needed knowledge and understanding.
Enter service menu
Press and hold MTR MNU button while switching on the transceiver – enters in
service menu. Long press of MTR MNU button stores parameters changed and leaves
the menu. Short press of RIT/XIT CL discards changes made and leaves the menu.
It is recommended prior making any changes to the service functions parameters – to
write down all values in bellow table:
No
Service menu function
parameter
70
F-cAL (frequency calibration)
71
IF (intermediate frequency)
72
bFocAL (BFO calibration)
73
S-FuL (S-meter full scale calibration)
74
S-9 (S-meter S9 calibration)
75
PA-t (PA temperature calibration)
Must be aligned for proper t
76
Ic (current consumption)
Must be aligned for proper Ic
77
Uc (supply voltage)
Must be aligned for proper Uc
78
Po-25 (output power at 25W)
80
210U (Low pass filter high voltage)
Must be aligned for proper Uc
Function selection is controlled by encoder 3 or UP REC and DOWN PLY buttons.
Parameter selection is controlled by encoder 4