Parani-SD1000U
User Guide
Version 1.0.0
2010-10-22
Страница 1: ...Parani SD1000U User Guide Version 1 0 0 2010 10 22 ...
Страница 2: ...ces resulting from system failure is the user s responsibility This device is not approved for life support or medical systems Changes or modifications to this device not explicitly approved by Sena Technologies will void the user s authority to operate this device Precautions and Safety Product Parani SD meets the USB standards Do not wire with non standard products Damage to your products may re...
Страница 3: ...ation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation IMPORTANT NOTE FCC RF Radiation Exposure Statement This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment This equipment should be installe...
Страница 4: ...02 TA Revision History Revision Date Name Description V1 0 0 2010 10 22 JH Park Initial Writing ...
Страница 5: ...figuration 26 3 3 AT Commands 27 3 3 1 AT MULTI n 27 3 3 2 AT MLIST 27 3 3 3 ATHx ATHbdaddr 27 3 3 4 ATOx ATObdaddr 27 3 4 Notes 28 4 RF Information 29 4 1 Radio Frequency Range 29 4 2 Number of Frequency Channel 29 4 3 Transmission Method 29 4 4 Modulation Method 29 4 5 Radio Output Power 29 4 6 Receiving Sensitivity 29 4 7 Power Supply 29 Appendix A AT Commands 29 A 1 Terminology 29 A 1 1 AT Com...
Страница 6: ...de default 0 29 B 5 S10 Enable Response Message default 1 29 B 6 S11 Enable Escape default 1 29 B 7 S12 Clear Data Buffer When Disconnected default 1 29 B 8 S13 Enable DCD Signal default 1 29 B 9 S14 Enable DTR Transfer default 1 29 B 10 S15 Enable Disconnect by DTR default 0 29 B 11 S22 Faster Connection default 0 29 B 12 S23 Intercharacter Timeout Setting default 0 29 B 13 S24 Maximum Number of ...
Страница 7: ...Trouble Shooting 29 C 1 No Data Transmission 29 C 1 1 COM Port Settings 29 C 2 Data Loss or Malfunctioning 29 C 2 1 Hardware Flow Control 29 C 2 2 Response Message 29 C 3 Transmission Delay 29 C 3 1 RF Processing Delay 29 C 3 2 RF Transmission Environment 29 Appendix D Warranty 29 D 1 GENERAL WARRANTY POLICY 29 D 2 LIMITATION OF LIABILITY 29 D 3 HARDWARE PRODUCT WARRANTY DETAILS 29 D 4 SOFTWARE PR...
Страница 8: ...equipment Its detachable antenna has the ability to optimize the quality and distance of wireless communications SD1000U supports FHSS Frequency Hopping Spread Spectrum which is a technique native to Bluetooth that allows the SD1000U minimize radio interference while decreasing the likelihood of over air hijacking SD1000U also supports authentication and Bluetooth data encryption SD1000U can be co...
Страница 9: ...umidity 90 Non condensing Physical properties Dimension L x W x H 68 x 22 x 11 5 mm Weight 14g Warranty 3 year limited warranty Note Bluetooth v2 0 supports improved AFH function AFH function is to mitigate the interference between WiFi and Bluetooth radios by automatically avoiding the active WiFi channel from Bluetooth link However AFH does not provide a complete solution making WiFi and Bluetoo...
Страница 10: ...eeds to be installed on the computer Windows XP and later versions already include the USB driver When Windows asks for the location of the USB driver you can select the option to install the software automatically as shown in Figure 2 7 You can also choose to install the driver from the CD included if the driver is not installed correctly for some reason Figure 2 1 USB Driver Installation ...
Страница 11: ...luetooth device SD1000U in Mode1 is to be a master and tries to connect the last connected Bluetooth device SD1000U always stores the BD address of the Bluetooth device to which SD1000U has connected last When Parani SD1000 is initially used or after hardware reset there is no BD address stored in SD1000U In this case Mode1 will not be able to work properly The mode change to Mode1 can be made aft...
Страница 12: ...e parity At this time master and slave are Parani SD Parani ESD or Parani MSP series But 7 data bit and none parity is not support 2 6 Hardware Flow Control SD1000U plugged into its host system transmits data from host to the other side Bluetooth device This data is saved temporarily in the internal buffer of SD1000U and sent repeatedly until the transmission is completed packet by packet When the...
Страница 13: ...n be set Upper 3 dipswitches are used for setting the baud rate and bottom dipswitch is used for setting hardware flow control option If the baud rate needs to a baud rate not shown below ParaniWIN or terminal program should be used to set these speeds To set a baud rate not shown below the dipswitches should be in the S W Config setting When in the S W Config setting the baud rate will go back to...
Страница 14: ...n will be deactivated automatically The SD1000U will not send the response messages such as OK Connect and Disconnect Table 2 6 Pairing Process by Pairing Button SD1 Status LED SD2 Status LED 1 Factory reset Mode0 Mode LED turns on 1 Factory reset Mode0 Mode LED turns on 2 Push pairing button Mode3 Mode LED blinks 3 times every 3 seconds 2 Push pairing button Mode3 Mode LED blinks 3 times every 3 ...
Страница 15: ...MultiWizard Multi Configuration MS Windows 98SE or Higher ParaniUpdater Firmware Update MS Windows 98SE or Higher 2 11 ParaniWIN ParaniWIN is a program that runs on Microsoft Windows for the configuration of SD1000U Install ParaniWIN on your computer Plug a SD1000U into the serial port of the computer and turn on the power Run ParaniWIN Figure 2 1 Serial Port Setting Set each option properly and c...
Страница 16: ...ndow Figure 2 4 Information Window Serial port settings can be changed by Start Configuration and ParaniWIN Configuration of ParaniWIN in the menu bar at upper left corner of the window without re running the ParaniWIN program ...
Страница 17: ...options Authentication and Encryption If you enable the Authentication option you must also enter a Pin Code value If the authentication is enabled the connection between the Master and Slave device must share the same Pin Code In case that SD1000U connects to another Bluetooth device that requires authentication you must know the other device s Pin Code In general most Bluetooth devices have a pi...
Страница 18: ...Tcommand mode the Baud Rate menu will be disabled Click Apply button to apply any changes made to the SD1000U Connection out icon will show the following window to search and connect other Bluetooth devices Figure 2 7 Connection out Window Click Search button to search nearby Bluetooth devices Once several Bluetooth devices has been found select one of the devices and click the Connect button The ...
Страница 19: ...n push the STOP button at anytime in order to terminate the signal strength test The signal strength test will continue until the STOP button is pushed If you close the ParaniWIN Window without pushing the STOP button you must restart SD1000U to terminate the test Connection in icon will show the following window which enables the SD1000U to wait for a connection from another Bluetooth device If t...
Страница 20: ...w If the Connection Wizard icon is clicked an easy to use pairing menu will appear Figure 2 10 Connection Wizard Window In this example we will refer to the two SD1000Us as SD1 and SD2 respectively To use this menu please do the following ...
Страница 21: ...sure that each SD1000U s connect LED is on At this point when both SD1000U s restart the connection will be established automatically 2 12 Parani Multi Wizard Parani Multi Wizard is the software tool for multiple connection mode configurations of the Parani SD and Parani ESD products Figure 2 11 Parani Multi Wizard Window Parani Multi Wizard supports the Wizard mode and the Manual mode The Wizard ...
Страница 22: ...cted which can be useful when only some parts of the settings are changed If the AT Command Response Disable check box is checked on the AT command responses such as OK ERROR CONNECT DISCONNECT are suppressed 2 13 ParaniUpdater SD1000U supports firmware updates You can download new firmware images for the SD1000U at http www sena com With the ParaniUpdater you can update the firmware of SD1000U by...
Страница 23: ...s HyperTerminal program is included as part of the operating system Parani SD1000 provides some extended AT commands for configuration of the SD1000U This manual will explain the method using HyperTerminal If you need to install HyperTerminal click start setting control panel add remove programs For more precise details on HyperTerminal installations please refer to Microsoft Windows Help section ...
Страница 24: ... communication HyperTerminal Select the Serial port that SD1000U is connected to Select the Serial port setting in the window displayed please make sure the serial settings in Hyperterminal are set to the same settings as the SD1000U s serial settings To view the AT commands that are being typed you will need to enable the local echo option Go to File Properties Settings ASCII setup and select the...
Страница 25: ...p Mode a master unit can connect to maximum 4 slave units at the same time and they transfer data bi directionally as in Figure 3 1 Figure 3 2 Node Switching Mode In Node Switching Mode the master unit maintains multiple connections with maximum 4 slave units but only one connection with one slave unit is active and data is transferred as shown in Figure 3 2 Active slave is selected by AT commands...
Страница 26: ... Connection Automatic Connection ATD000195000001 CONNECT000195000001 OK ATD000195000002 CONNECT000195000002 OK ATD000195000003 CONNECT000195000003 OK ATD000195000004 CONNECT000195000004 ATS46 000195000001 OK ATS54 000195000002 OK ATS55 000195000003 OK ATS56 000195000004 OK AT MULTI 1 or AT MULTI 2 OK AT BTMODE 1 After rebooted automatically master tries to connect to slaves After input the BD addr...
Страница 27: ...slaves ATHx ATH1 ATH2 ATH3 ATH4 Disconnect the slave which belongs to the TASK x ATHbdaddr ATH000195000001 Disconnect the slave with specified BD address 3 3 4 ATOx ATObdaddr Using the ATO command the communication status with the last active slave or a specific slave can be set to online only in Node Switching Mode Table 3 4 ATO ATO Communicate with the slave recently communicated ATOx ATO1 ATO2 ...
Страница 28: ...cations The master unit would try to connect all slave units specified by S register 46 54 55 and 56 If non existing or inactive slave addresses are entered in these S registers the overall performance will degrade due to frequent connection trials to non existing inactive slaves It may also force disconnections for overall performance and outputs disconnect messages repeatedly Node switching mode...
Страница 29: ...tion Method GFSK Gaussian filtered Frequency Shift Keying Pi 4 DQPSK pi 4 rotated Differential Quaternary Phase Shift Keying 8DPSK 8 phase Differential Phase Shift Keying 4 5 Radio Output Power Products Radio Output Power Parani SD1000U 14dBm 4 6 Receiving Sensitivity Products Receiving Sensitivity Parani SD1000U 88dBm 4 7 Power Supply Products Power Supply Parani SD1000U USB 5 0V ...